KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Absolute pressure transducer P3IC/P3ICP

Special features

  • For static and dynamic pressure variance, pressure peaks and pressure oscillations
  • Nominal (rated) pressure 10 bar to 3000 bar
  • Strain gage measurement principle
  • Corrosion resistant
  • PT100 for temperature compensation in two-wire circuit

Type

1-P3IC / P3ICP

Accuracy class

0.2

0.15

0.2

0.15

0.1

0.2

Mechanical input quantities

Pressure type

absolute pressure

Measuring range, 0 bar …

bar

10

20

50

100

200

500

750

1000

2000

2500

3000

Initial value

bar

0

Mechanical values per VDI/VDE 2600, related to full scale value

Operating range

at reference temperature

Overload limit

at reference temperature

Test pressure

Permissible pressure at dyn. load

Permissible oscillation width at dyn. load per DIN 50 100

%

%

%

%

%

0 … 200 0 … 150

250 200

250 200 150

100

70

Dead volume

mm3

2000

800

900

Control volume

mm3

9

7

1.5

Output characteristics

Output signal span

mV/V

2

1,5

Characteristic curve deviation (initial point)

%

0.20

0.15

0.20

0.15

0.10

0.20

Repeatability per DIN 1319

%

<±0.05

Fundamental resonance frequency

kHz

13

15

26

38

67

100

Input resistance at reference temperature Output resistence at reference temperature Insulation resistance

Ω

Ω

350 ±5

350 ±1.5

5000

Electrical strength

V

90

Sensitivity tolerance

%

0.2

<±0.15

Zero signal tolerance

%

<±1

Creep upon unloading 15 min.

%

0.2

0.1

±0.05

±0.03

Effect of temperature on sensitivity in the nominal (rated) excitation voltage range per 10K, rel. to actual value

in the nominal (rated) temperature range in the operating temperature range

%

%

±0.1

±0.2

Effect of temperature on zero signal in the nominal (rated) excitation voltage range per 10K, rel. to nominal (rated) sensitivity

in the nominal (rated) temperature range in the operating temperature range

%

%

±0.1

±0.15

Excitation voltage

Reference excitation voltage

V

5

Nominal (rated) excitation voltage

V

0.5 … 7.5

Operating range

V

0.5 … 12

Ambient conditions

Permissible voltage between measuring circuit and transducer ground at reference temperature

V

50

Material

of parts in contact with the measurement medium

of parts in contact with the environment

1.4542 / 1.4301 1.4542 1.4548

1.4301 / 1.454 / 1.4542, chloroprene / silicone

Reference temperature

Nominal (rated) temperature range Limiting temprature range

Storage temperature range

oC

°C

°C

°C

23

-10 … +80

-40 … +100 (… 120°C up to 24 hours)

-50 … +100

Absolute pressure transducer P3IC/P3ICP - datasheet PDF, 0.48 Kb