Type |
1-P3IC / P3ICP | |||||||||||
Accuracy class |
0.2 |
0.15 |
0.2 |
0.15 |
0.1 |
0.2 | ||||||
Mechanical input quantities | ||||||||||||
Pressure type |
absolute pressure | |||||||||||
Measuring range, 0 bar … |
bar |
10 |
20 |
50 |
100 |
200 |
500 |
750 |
1000 |
2000 |
2500 |
3000 |
Initial value |
bar |
0 | ||||||||||
Mechanical values per VDI/VDE 2600, related to full scale value Operating range at reference temperature Overload limit at reference temperature Test pressure Permissible pressure at dyn. load Permissible oscillation width at dyn. load per DIN 50 100 |
%
% % %
% |
0 … 200 0 … 150
250 200 250 200 150 100
70 | ||||||||||
Dead volume |
mm3 |
2000 |
800 |
900 | ||||||||
Control volume |
mm3 |
9 |
7 |
1.5 | ||||||||
Output characteristics | ||||||||||||
Output signal span |
mV/V |
2 |
1,5 | |||||||||
Characteristic curve deviation (initial point) |
% |
0.20 |
0.15 |
0.20 |
0.15 |
0.10 |
0.20 | |||||
Repeatability per DIN 1319 |
% |
<±0.05 | ||||||||||
Fundamental resonance frequency |
kHz |
13 |
15 |
26 |
38 |
67 |
100 | |||||
Input resistance at reference temperature Output resistence at reference temperature Insulation resistance |
Ω Ω MΩ |
350 ±5 350 ±1.5 5000 | ||||||||||
Electrical strength |
V |
90 | ||||||||||
Sensitivity tolerance |
% |
<± 0.2 |
<±0.15 | |||||||||
Zero signal tolerance |
% |
<±1 | ||||||||||
Creep upon unloading 15 min. |
% |
0.2 |
0.1 |
±0.05 |
±0.03 | |||||||
Effect of temperature on sensitivity in the nominal (rated) excitation voltage range per 10K, rel. to actual value in the nominal (rated) temperature range in the operating temperature range |
% % |
±0.1 ±0.2 | ||||||||||
Effect of temperature on zero signal in the nominal (rated) excitation voltage range per 10K, rel. to nominal (rated) sensitivity in the nominal (rated) temperature range in the operating temperature range |
% % |
±0.1 ±0.15 | ||||||||||
Excitation voltage | ||||||||||||
Reference excitation voltage |
V |
5 | ||||||||||
Nominal (rated) excitation voltage |
V |
0.5 … 7.5 | ||||||||||
Operating range |
V |
0.5 … 12 | ||||||||||
Ambient conditions | ||||||||||||
Permissible voltage between measuring circuit and transducer ground at reference temperature |
V |
50 | ||||||||||
Material of parts in contact with the measurement medium of parts in contact with the environment |
|
1.4542 / 1.4301 1.4542 1.4548 1.4301 / 1.454 / 1.4542, chloroprene / silicone | ||||||||||
Reference temperature Nominal (rated) temperature range Limiting temprature range Storage temperature range |
oC °C °C °C |
23 -10 … +80 -40 … +100 (… 120°C up to 24 hours) -50 … +100 |
Absolute pressure transducer P3IC/P3ICP - datasheet | PDF, 0.48 Kb |