KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

QuantumX MX440B

Special features

  • 4 individually configurable inputs (electrically isolated)
  • Connection of more than 12 transducers technologies
  • Individual data rates up to 40kHz per channel, active low pass filter
  • 24−bit A/D converter per channel for synchronous, parallel measurements
  • TEDS support
  • Supply voltage for active transducers (DC): 5 V ... 24 V

General specifications

Inputs

Number

4, electrically isolated from each other and from the supply voltage

Transducer technologies

Strain gauge full and half bridge, Quater-bridge with 1−SCM−SG120/350, inductive full and half bridge,

piezoresistive full bridge, IEPE (ICPâ), potentiometric

transducers, three voltage ranges, current (0 … 20 mA); resistance (e. g. PTC, NTC, KTY); resistance thermometer

(PT100, PT1000); thermocouples (K, N, E, T, S, ...) with cold junction in the plug (1−THERMO−MXBOARD). IEPE (via external EICP adapter)

Frequency, pulse counting, SSI, incremental rotary encoder (connectors 5−8 only).

A/D converter

24 Bit Delta Sigma converter

Data rates (adjustable by software, default: HBM Classic)

S/s

Dezimal: 0,1 …40.000

HBM Classic: 0,1 … 38.400

Signal bandbwidth

kHz

7.2

Aktive low-pass filter

Hz

Bessel, Butterworth, linear phase 0.01 ... 3000 (−3 dB), Filter OFF

Transducer identification

max. distance of the TEDS module

m

TEDS, IEEE 1451.4

100

Transducer connection

D-SUB-15HD

Supply voltage range (DC)

V

10 ... 30 (24 V nominal (rated) voltage)

Supply voltage interruption

max. 5 ms at 24 V

Power consumption

W

< 9

without adjustable transducer excitation

with adjustable transducer excitation

W

< 12

Transducer Excitation (active transducers) Adjustable supply voltage (DC)

Maximum output power

V W

5 ... 24; adjustable for each channel

0.7 each channel / a total of 2

Ethernet (data link) Protocol/addressing Connection

Max. cable length to module

m

10Base-T / 100Base-TX TCP/IP (direct IP address or DHCP)

8P8C plug (RJ-45) with twisted pair cable, Streaming

(CAT-5)

100

Synchronization options

EtherCAT

IRIG−B (B000 bis B007; B120 bis B127) IEEE1588 (PTPv2), NTP

IEEE1394b FireWire (only QuantumX, automatically, recommended)

via CX27 EtherCAT Gateway

via MX440A/B- or MX840A/B-input channel Ethernet based Network Time Protocol

IEEE1394b FireWire (module synchronization, data link,

MBaud

IEEE 1394b (HBM modules only)

optional supply voltage)

Baud rate

400 (approx. 50 MByte/s)

Max. current from module to module

A

1.5

Max. cable length between the nodes

m

5

Max. number of modules connected in series (daisy chain)

12 (=11 Hops)

Max. number of modules in a IEEE1394b FireWire system

(including hubs, backplane)

24

Max. number of hops

14

Nominal (rated) temperature range

°C [°F]

−20 ... +65 [−4 ... +149]

Storage temperature range

°C [°F]

−40 ... +75 [−40 ... +167]

Rel. humidity

%

5 ... 95 (non condensing)

Protection class

III

Degree of protection

IP20 per EN 60529

Mechanical tests

m/s2

50

Vibration (30 min)

Shock (6 ms)

m/s2

350

QuantumX MX440B - datasheet PDF, 0.34 Kb