KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

QuantumX MX879B

Special features

  • 8 individually configurable analog outputs (electrically isolated, can be filtered)
  • 32 digital inputs/outputs, freely programmable
  • Mathematics unit (real-time computation)
  • Signal generator, signals: standard types or individuel

General specifications

Supply voltage range (DC)

V

10 ... 30 (24 V nominal (rated) voltage)

Analog outputs

Number

8, electrically isolated from each other and from the supply

Digital In/Outputs

Number

32, individually freely configurable as input or output

Type of connection

Plug terminal: Phönix Contact FMC−1,5/8−ST−3,5−RF (plug included in scope of supply)

Supply voltage interruption

max. for 5 ms at 24 V

Power consumption

W

7

Ethernet (data link) Protocol/addressing Connection

Max. cable length to module

m

10Base-T / 100Base-TX TCP/IP (direct IP address or DHCP)

8P8C plug (RJ-45) with twisted pair cable (CAT-5) 100

FireWire (module synchronization, data link, optional supply

MBaud

IEEE 1394b (HBM modules only)

voltage)

Baud rate

400 (approx. 50 MByte/s)

Max. current from module to module

A

1.5

Max. cable length between the nodes

m

5

Max. number of modules connected in series (daisy

12 (=11 hops)

chain)

Max. number of modules in a FireWire system (including

hubs, backplane)

24

Max. chain of hops

14

Synchronization

EtherCAT

NTP

IRIG−B (B000 to B007; B120 to B127)

FireWire (automatically, recommended) via CX27

via Ethernet

via MX440A- or MX840A input channel

Nominal (rated) temperature range

°C [°F]

−200... +60 [−4 ... +140]

Operating temperature range

°C [°F]

−20 ... +65 [−4 ... +149]

Storage temperature range

°C [°F]

−40 ... +75 [−40 ... +167]

Rel. humidity

%

5 ... 95 (non condensing)

Protection class

III

Degree of protection

IP20 per EN60529

Mechanical tests

m/s2

50

Vibration (30 min)

Shock (6 ms)

m/s2

350

EMC requirements

Störaussendung EN55011, Klasse B mit Klappferrit auf Spannungsversorgungsleitung, 12 cm vom Gerät entfernt anzubringen. Ferrit liegt bei.

Störaussendung Klasse A wird ohne Klappferrit eingehalten

per EN 61326

Dimensions, horizontal (W x H x D)

mm

mm

52.5 x 200 x 122 (with case protection)

44 x 174 x 119 (without case protection)

Weight, approx.

980

QuantumX MX879B - datasheet PDF, 0.11 Kb