Type |
ELCB2 HS | |
Maximum capacity (Emax) |
220 kg; 550 kg; 1.1 t; 1.76 t | |
Accuracy class |
1 % | |
Sensitivity (Cn) |
mV/V |
1.94 ±1 % |
Temperature effect on sensitivity (TKC) |
% of Cn / 10 K |
±0.4000 |
Temperature effect on zero balance (TK0) |
±0.4000 | |
Hysteresis error (dhy) |
% of Cn |
±0.1000 |
Non‐linearity (dlin) |
±0.1000 | |
Creep (dcr) over 30 min. |
±0.1000 | |
Input resistance (RLC) |
Ω |
> 350 |
Output resistance (R0) |
350 ±2 | |
Reference excitation voltage (Uref) |
V |
5 |
Nominal range of excitation voltage (BU) |
0.5 ... 15 | |
Insulation resistance (Ris) |
GΩ |
> 5 |
Nominal temperature range (BT) |
°C [°F] |
-10 ... +40 [+14 ... +104] |
Service temperature range (Btu) |
-30 ... +70 [-22 ... +158] | |
Storage temperature range (Btl) |
-50 ... +85 [-58 ... +185] | |
Safe load limit (EL) |
% of Emax |
150 |
Breaking load (Ed) |
300 | |
Lateral load limit (Elq) |
100 | |
Permissible dynamic load (Fsrel) (vibration amplitude according to DIN 50100) |
70 | |
Deflection at Emax (snom), approx. |
mm |
0.5 (1.76t = 1.4mm) |
Weight (G) approx. |
kg |
0.9 |
Protection class accord. to EN60529 (IEC529) |
|
IP 68 / IP 69K |
Material: Measuring element Cable entry Cable sheath Application protection (sealing) |
|
Stainless steel Stainless steel (Gasket: Viton®) TPE hermetically sealed |
Beam Load Cell ELC - datasheet | PDF, 0.06 Kb |