KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Canister Load Cell C16A

Special features

  • The function of self
  • Maximum load: 20 t ... 100 t 400 t
  • Easy installation
  • Stainless steel, laser welded, IP68/IP69K
  • Verification for commercial applications
  • С16А

    - Up to 5000 divisions (OIML R60)

    - Up to 10,000 divisions (NTEP class III LM)

    С16А 100/200/400 t

    - 100 t to 3000 divisions (OIML R60 D1 + C3)

    - 200 MT, 400 MT to 1000 divisions (OIML R60 D1)

  • Optimized for parallel connection with corner correction
  • Meets the EMC requirements according to EN 45 501:2015
  • Explosion-proof version according to ATEX and lECEx (optional)

Type

C16A D1

C16A C3

C16A C4

Maximum capacity (Emax)

20 t

30 t

40 t

60 t

100 t

20 t

30 t

40 t

60 t

100 t

20 t

30 t

40 t

60 t

Accuracy class according to OIML R60

D1 (0.0330 %)

C3 (0.0170 %)

C4

Number of load cell verification intervals (nLC)

1000

(10000 NTEP III LM)

3000

4000

Minimum load cell verification inter­ val (vmin)

% of Emax

0.0200

(0.0068 NTEP III LM)

0.0100

0.0083

0.0167

0.0100

0.0083

[Option: 0.0050]

Nominal (rated) sensitivity (Cn)

mV/V

2

Sensitivity tolerance 1)

%

±0.5 1)

Temperature coefficient of sensitiv­ ity (TCS) 2)

% of Cn/1

0 K

2)

2)

2)

Temperature coefficient of zero sig­ nal (TC0)

±0.0285

±0.0140

±0.0116

±0.0234

±0.0140

±0.0116

Relative reversibility error (dhy) 2)

% of Cn

±0.0330 2)

±0.0170 2)

±0.0140

Non-linearity (dlin) 2)

±0.0300 2)

±0.0180 2)

±0.0120

Creep upon loading (dcr) over 30 min.

±0.0330

±0.0167

±0.0125

Minimum dead load output return (DR), 30 min.

±0.0330 (±0.0150 NTEP III LM)

±0.0167

±0.0125

Repeatability error (max. change in load cell output for repeated loading)

±0.005

Input resistance (RLC) (black-blue)

Ω

700 ±20

Output resistance (R0) 1) (red-white)

706 ±3.5 1)

Reference excitation voltage (Uref)

V

5

Nominal (rated) range of the excitation voltage (BU)

0.5 ... 12

Insulation resistance (Ris)

> 5

Nominal (rated) range

of the ambient temperature (BT)

°C

-10 ... +40

Operating temperature range (Btu)

-50 ... +70

Storage temperature range (Btl)

-50 ... +85

Limit load (EL)

% of Emax

150

Breaking load (Ed)

> 350

Relative permissible oscillatory stress (Fsrel)

(oscillation bandwidth as per DIN

50100 with 10,000,000 load changes)

70

Maximum capacity (Emax)

20 t

30 t

40 t

60 t

100 t

Deflection at Emax (snom), approx.

mm

0.65

0.75

0.85

1.22

1.57

Weight (G) with cable, approx.

kg

2.1

2.3

2.9

3.7

8

Degree of protection per EN60529 (IEC529)

IP68 (test conditions 1 m water column/100 h) IP69 K (water at high pressure, steam jet cleaning)

Material: Measuring body + housing Cable entry

Seal

Cable sheath

stainless steel 3)

stainless steel4) (Emax 100 t: nickel-plated brass)

Viton® (Emax 100 t: silicone) thermoplastic elastomer

1) Because of the off-center load compensation, the sensitivity and output resistance are matched in such a way that when there is eccentric loading, the scale display is within the permissible error limits.

2) The values for non-linearity (dlin), relative reversibility error (dhy) and temperature coefficient of sensitivity (TCS) are recommended values. The sum of these values is within the cumulated error limit for pLC = 0.7 according to OIML R60 or NTEP.

3) As per EN 10088-1

Canister Load Cell C16A 100...200t - datasheet PDF, 0.15 Kb
Canister Load Cell C16A - datasheet PDF, 0.14 Kb