KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Canister Load Cell C16i

Special features

  • Digital output signal (RS‐485 / 4‐wire)
  • Nominal (rated) loads: 20 t ... 60 t
  • Self restoring rocker pin
  • Simple to install
  • Stainless steel material, laser welded, IP68
  • Legal for trade verification according to OIML R60 up to 3000 d
  • Legal for trade verification according to NTEP III LM up to 10 000 d
  • Meets EMC / ESD requirements according to EN 45 501
  • Inbuild overvoltage protection

Type

C16i D1

C16i C3

Nominal (rated) load (Emax)

20 t

30 t

40 t

60 t

20 t

30 t

40 t

60 t

Accuracy class according to OIML R60

Max. numbers of LC verification intervals (nLC)

D1 (0.0330 %)

1000

C3 (0.0180 %)

3000 (10 000 NTEP III LM)

Min. load cell verification interval (vmin)

%

of Emax

0.0200

0.0100

(0.006 NTEP III LM)

0.0083

(0.006 NTEP III LM)

Min. scale verification interval (emin) according to EN 45 501

[... LC = max. Number of load cells]

kg

-

-

-

-

5

[6 LC]

10

[10 LC]

10

[10 LC]

10

[6 LC]

20

[10 LC]

10

[4 LC]

20

[10 LC]

Sensitivity (Cn)

digit

1 000 000

Sensitivity tolerance

%

±0.03

Temperature effect on sensitivity (TKC) 1)

% of Cn

/ 10 K

±0.0250 1)

±0.0080 1)

Temperature effect on zero signal (TK0)

±0.0285

±0.0140

±0.0116

Hysteresis error (dhy) 1)

% of Cn

±0.0330 1)

±0.0170 1)

Non‐Linearity (dlin) 1)

±0.0300 1)

±0.0180 1)

Creep (dcr), 30 min.

±0.0330

±0.0167

Min. dead load output return (DR), 30 min.

±0.0330

±0.0167 (±0.0150 NTEP III LM)

Reference excitation voltage(Uref)

V (DC)

12

Nominal range of excitation voltage (BU)

8.5 ... 15 2)

Current consumption

mA

50 2)

Resolution

Bit

20 (at 1 Hz)

Measuring rate

1 / sec

200 | 100 | 50 | 25 | 12 | 6 | 3 | 2 | 1

Filter mode 0

Hz

8 ... 0.05 (Low pass filter)

Filter mode 1

8 ... 3 (Low pass filter)

Asynchrone Interface

RS‐485 / 4‐wire (Cable lenght up to 500 m)

Baudrate

Baud

1200 ... 115200

Number of bus adresses

max. 32

Nominal temperature range (BT)

°C [°F]

-10 ... +40 [14...104]

Service temperature range (Btu)

-20 ... +70 [-4...158]

Storage temperature range (Btl)

-50 ... +85 [-58...185]

Limit load (EL)

%

of Emax

150

Breaking load (Ed)

> 350

Permissible dynamic load (Fsrel) (vibration amplitude acc. to DIN 50100)

70

Nominal (rated) load (Emax)

20 t

30 t

40 t

60 t

20 t

30 t

40 t

60 t

Deflection at Emax (snom), approx.

mm

0.65

0.75

0.85

1.22

0.65

0.75

0.85

1.22

Weight (G) with cable, approx.

kg

2.2

2.4

3.0

3.8

2.2

2.4

3.0

3.8

Protection class according to EN60529 (IEC529)

IP68 (test conditions 100 h at 1 m water column) IP69 K (water at high pressure, steam jet cleaning)

Material: Meas. body + housing Cable fitting

Sealing Cable‐sheath

stainless steel stainless steel Viton

thermoplastical elastomer

Canister Load Cell C16i - datasheet PDF, 0.18 Kb