KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Beam Load Cell Z6R

Special features

  • Nominal (rated) loads: 20 kg … 200 kg
  • Welded-on robust cover
  • Load cells made of rust-resistant materials
  • Easy to clean
  • Same dimensions like Z6F
  • Verifiable up to 3000 divisions, test report as per OIML R60
  • Six-wire circuit
  • Optimized for parallel connection
  • Meets EMC requirements as per EN 45501:2015
  • Options: Ex-protection designs as per ATEX and IECEx

Type

Z6R…

Accuracy class to OIML R 60

Number of scale intervals (nLC)

D1

1000

C3

3000

Nominal (rated) load (Emax)

kg

20; 50; 100; 200

Minimum scale division (vmin)

% of Emax

0.0360

0.0090

Nominal (rated) sensitivity (Cn)

mV/V

2

Sensitivity tolerance with load appl. in spec. direction

%

±0.1

±0.05

Temperature coefficient of sensitivity (TCS)1)

% of Cn/10 K

±0.0500

±0.0080

Temperature coefficient of zero signal (TK0)

±0.0500

±0.0125

Relative reversibility error (dhy)1)

% of Cn

±0.0500

±0.0170

Non linearity (dlin)1)

±0.0500

±0.0180

Load creep (dDR) in 30 min.

±0.0490

±0.0166

Input resistance (RLC)

Ù

350...480

Output resistance (R0)

356 ±0.2

356 ±0.12

Reference voltage (Uref)

V

5

Nominal supply voltage range (Bu)

0.5...12

Insulation resistance (Ris)

> 5

Nominal ambient temperature range (BT)

oC

-10...+40

Operating temperature range (Btu)

-30...+70

Storage temperature range (Btl)

-50...+85

Limit load (EL)

% of Emax

150

Breaking load (Ed)

:::300

Beam Load Cell Z6R - datasheet PDF, 0.09 Kb