Type
Accuracy class |
|
VKIA405 0.1 |
Resistor network for off-center load compensation Nominal (rated) voltage) Voltage supply |
Ω VDC VDC |
0.39...5.71 (in 15 steps)
24
12...30 |
Nominal temperature range |
°C [°F] |
−10...+50 [+14...+122] |
Operating temperature range |
−20...+70 [−4...158] | |
Storage temperature range |
|
−40...+85 [−40...185] |
Humidity, rel., non-condensing |
% |
5...85 |
Weight, approx.
Degree of protection according to EN 60529 (IEC 529) |
kg |
1
IP65 (dust-tight and protected against water jets) |
Material: Housing Sleeve nut
Clamping cone |
|
Sheet steel powder-coated housing: RAL 7035
4 x M12, a.f. 14; 2 Sx M16, a.f.17 nickel-plated brass
Neoprene |
|
| |
Integrated electronics |
| |
Bridge resistance of each transducer (max. 4) |
Ω |
300...1000 |
Cable length of each transducer |
m |
6 |
Bridge excitation voltage1) |
VAC |
5 |
Max. measuring range |
mV/V |
± 3.0 |
Measuring signal resolution |
Bit |
24 (with 1Hz) |
Sampling rate (depending on output format and baud rate) |
Hz |
200; 100; 50; 25; 12; 6; 3; 2; 1 |
Cut-off frequency of the digital filter, adjustable; with -3dB |
Hz |
20...0.05 |
Cable lengths between electronics and computer with RS-485 |
m |
< 500 |
Non-linearity, related to the sensitivity |
% |
± 0.025 |
Effect of temperature per 10K |
% |
± 0.02 |
on the zero point, related to the full scale value | ||
on the measuring sensitivity, related to the actual value |
% |
± 0.05 |
Serial interfaces electrical level (RS-485, differential)
Baud rate, adjustable |
V
Baud |
Low: B-A < 0.35 High: B-A > 0.35 1 200...115 200 |
Max. voltage on control output = supply voltage |
V |
12...30 |
Max. current load, control output |
mA |
500 |
Current consumption (with 350 W transducer) |
mA |
< 60 |
VKIA405 - datasheet | PDF, 0.21 Kb |