Type
|
|
KMR
|
Nominal (rated) force
|
kN
|
20
|
40
|
60
|
100
|
200
|
300
|
400
|
Sensitivity range
|
mV/V
|
1.7 ¼ 2.3*)
|
Effect of temperature on sensitivity per 10 K
in the nominal (rated) temperature range
|
%
|
1
|
Temperature effect on the zero signal/10 K
in the nominal (rated) temperature range
|
%
|
0.5
|
Non‐linearity
|
%
|
10
|
Relative reversibility error, rel. to full scale value
|
%
|
10
|
Repeatability
|
%
|
1
|
constant mounting position
|
different mounting positions
|
%
|
10
|
Creep over 30 min., at room temp.
|
%
|
2
|
Input resistance at room temp.
|
Ohm
|
>345
|
Output resistance at room temp.
|
Ohm
|
300 ¼ 400
|
Insulation resistance
|
GOhms
|
>5
|
Reference excitation voltage
|
V
|
5
|
Operating range of excitation voltage
|
V
|
0.5 ¼ 5
|
0.5 ¼ 12
|
Nominal (rated) temperature range
|
oC
|
‐10 ¼ +70
|
Operating temperature range
|
oC
|
‐10 ¼ +70
|
Storage temperature range
|
oC
|
‐30 ¼ +85
|
Limit force
|
%
|
150
|
Breaking force
|
%
|
>500
|
Relative static lateral limit force
|
%
|
20
|
Nominal (rated) displacement±15 %
|
mm
|
0.06
|
0.06
|
0.06
|
0.08
|
0.11
|
0.21
|
0.32
|
Natural frequency±15 %
|
kHz
|
22
|
45
|
47
|
27
|
22
|
18
|
15
|
Weight without cable
|
g
|
5
|
7
|
12
|
32
|
40
|
50
|
70
|
Permissible dynamic loading (vibration bandwidth in accordance with DIN 30100)
|
%
|
50
|
Degree of protection as per DIN 40 050
|
|
IP 67
|