Type
|
CLP/...
|
Nominal (rated) force
|
Fnom
|
kN
|
7
|
26
|
62
|
|
Accuracy
|
Relative reversibility error
|
v
|
%
|
1
|
Relative linearity error
|
dlin
|
%
|
1
|
|
Electrical characteristics
|
Sensitivity (typical)1)
|
S
|
pC/N
|
-4.3
|
Insulation resistance
|
Ris
|
W
|
> 1013
|
Connection
|
Integrated cable, plug 10-32UNF
|
|
Temperature
|
Nominal (rated) temperature range
|
BT, nom
|
°C
|
-20 ¼ +120
|
Operating temperature range
|
BT, G
|
-20 ¼ +120
|
Storage temperature range
|
BT, S
|
-20 ¼ +120
|
|
Mechanical parameters
|
Max. operating force
|
FG
|
%
|
115
|
Limit force
|
FL
|
150
|
Breaking force
|
FB
|
200
|
Maximum bending moment with 2)
with Fz = 0% with Fz = 50% with Fz = 100%
|
M
|
Nm
|
0
5
0
|
0
35
0
|
0
134
0
|
Static lateral limit force 3)
|
FQ
|
% of Fnom
|
10
|
Nominal (rated) displacement
|
snom
|
mm
|
3
|
3.5
|
4.5
|
Fundamental resonance frequency
|
fG
|
kHz
|
105
|
120
|
140
|
Relative permissible oscillatory stress
|
Frb
|
% of Fnom
|
100
|
|
General information
|
Degree of protection per DIN 60529
|
IP65
|
Sensor material
|
Stainless steel, quartz
|
Cable sheath material
|
FPM (fluorinated rubber)
|
Potting material
|
Silicone
|
Cable length
|
m
|
0.5 or 1
|
Connector
|
10-32UNF
|
Ground
|
m
|
g
|
6.5
|
22
|
30
|
|
|
Specifications (data per VDI/VDE/DKD 2638 standards)b perm
1) Must be calibrated under mounting conditions
2) Fz is the force in the measurement direction
3) Related to a point of contact on the force application surface