Type |
|
DD1 |
Accuracy class |
|
0.1 |
Nominal displacement |
mm |
2.5 |
Nominal sensitivity (nominal output signal at nominal |
|
|
displacement) |
mV/V |
2.5 |
Sensitivity tolerance (deviation of the sensitivity from nominal |
|
|
sensitivity) |
% |
0.1 |
Temperature effect per 10 K in the nominal temperature range |
|
|
of the output signal, related to the actual value |
% |
<0.03 |
of the zero signal, related to the nominal sensitivity |
% |
<0.05 |
Linearity error including hysteresis, related to the nominal output |
|
|
signal |
% |
<0.05 |
Electrical principle of measurement |
Ω |
Strain gage full bridge |
Input resistance at reference temperature |
350 3 | |
Nominal range of supply voltage at reference temperature |
V |
1...6 |
Service range of supply voltage |
V |
1...10 |
Spring rate (restoring force of the measuring probe tip) |
N/mm |
approx. 0.23 |
Reference temperature |
°C [°F] |
+23 [+73.4] |
Nominal temperature range |
°C [°F] |
- 10...+60 [+14 +140] |
Service temperature range |
°C [°F] |
- 20...+70 [- 4...+158] |
Storage temperature range |
°C [°F] |
- 50...+70 [- 58...+158] |
Cable length
Weight (transducer without cable) |
m
g |
1.5
20 |
Strain Transducer DD1 - datasheet | PDF, 0.17 Kb |