Type |
TIM-PN | |
Supply | ||
Supply voltage |
VDC |
24 ±10% |
Galvanic isolation Torque, speed, PROFINET. Ethernet and supply voltage are electric- ally isolated from each other |
|
|
Isolation voltage |
V |
500 |
Voltage discontinuity Test based on PLC standard DIN EN 61131−2: 24 V −10% |
ms |
10 |
Power consumption Without supply to transducers |
W |
<5 |
Communication interface | ||
Ethernet Data link Protocol/addressing Plug connection Line length Cable type (minimum requirements) |
m |
IEEE 802.3, 10Base-T / 100Base-TX TCP/IP (direct address or DHCP), HTTP, UDP RJ45, 8-pin :::100 Cat-5, SFTP |
PROFINET IO |
m |
PROFINET Device, acc. to Specification V2.31 |
Function | ||
Data link |
IEEE 802.3, 100Base-TX | |
Plug connection |
RJ45 socket, shielded | |
Line length |
:::100 | |
Cable type (minimum requirements) |
|
Cat-5, shielded |
Baud rate |
Mbit/s |
:::100 |
Update rate |
kHz |
4 |
Slave synchronization |
|
No |
Cyclic process input data, max. (device −> controller) |
bytes |
1024 |
Cyclic process output data, max. (controller −> device) |
bytes |
1024 |
Configuration data |
kBytes |
:::8 |
Parameter data |
kBytes |
:::8 |
Minimum cycle time |
ms |
250 |
Conformance class |
C | |
Topology recognition |
LLDP, SNMP, MIB2 | |
Supported protocols |
|
RTC − Real Time Cyclic RT Class 1 RT Class 3 (IRT) RTA − Real Time Acyclic PTCP − Precision Transparent Clock Protocol (IRT) DCP − Discovery and Configuration LLDP − Link Layer Discovery SNMP − Simple Network Management Fast startup |
Control via PROFINET Parameter set (stored in the device, selected via PROFINET) Flags Torque transducer (via TMC), TIM-PN Torque / speed / power |
|
Zero balance / shunt trigger / parameter set selection 32
Status (diagnosis) Status (diagnosis), measured values, overflow |
Ambient conditions | ||
Nominal (rated) temperature range |
°C |
+10 … +60 |
Operating temperature range |
−10 … +60 | |
Storage temperature range |
−20 … +70 | |
Permissible relative humidity, non-condensing |
% |
10 … 90 |