KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Torque Transducer T10FH

Special features

  • Nominal (rated) torques: 100 kNVm, 130 kNVm, 150 kNVm, 200 kNVm, 250 kNVm, 300 kNVm
  • Nominal (rated) speeds from 2,000 rpm to 3,000 rpm
  • Short design
  • Version for rotating and non-rotating use
  • Without bearings or slip rings
  • Options: magnetic speed measuring sys- tem, 180 pulses/revolution; PTB calibration certificate per DIN 51309 or EA−10/14: class 0.5

Type

T10FH (rotating); option 2, code L

Accuracy class

0.1

Torque measuring system

Nominal (rated) torque Mnom

kN⋅m

100

130

150

200

250

300

for reference only

kft-lb

73.8

95.9

110.6

147.5

184.4

221.3

Nominal (rated) sensitivity (range between torque

= zero and nominal (rated) torque) Frequency output

Voltage output

Sensitivity tolerance (deviation of the actual output value at Mnom of nominal (rated) sensitivity)

Frequency output

in conjunction with HBM test report

in conjunction with PTB calibration certificate per DIN 51309 or EA-10/14

Voltage output

in conjunction with HBM test report

in conjunction with PTB calibration certificate per DIN 51309 or EA-10/14

kHz V

%

%

%

%

5

"10

"0.25

"0.4

"0.1

"0.1

"0.35

"0.5

"0.2

"0.2

Output signal at torque = zero

kHz

10

Frequency output

Voltage output

V

0

Nominal (rated) output signal

Frequency output

with positive nominal (rated) torque with negative nominal (rated) torque

Voltage output

with positive nominal (rated) torque with negative nominal (rated) torque

Load resistance Frequency output Voltage output

Long-term drift over 48 h

Voltage output

Measurement frequency range

Voltage output

Group delay time Frequency output Voltage output

Residual ripple

related to nominal (rated) sensitivity

kHz kHz

V V

kΩ kΩ

mV Hz

ms ms

mV

15 ("5 V symmetric)1) / 15 (12 V asymmetric)

5 ("5 V symmetric)1) / 5 (12 V asymmetric)

+10

−10

> 2

> 5

"3

0 ... 1000 (−3 dB)

0.15

0.9

40 (peak-to-peak)

Temperature influence per 10 K in the nominal

%

"0.1

temperature range

on the output signal, related to the actual value

of signal span

Frequency output

Voltage output

%

"0.2

on the zero signal, related to the nom. sensitivity

Frequency output

%

"0.05

Voltage output

%

"0.15

Max. modulation range2)

kHz

4 ... 16

Frequency output

Voltage output

V

−10.5 ... +10.5 (typ. "11)

Power supply

V (DC)

18 ... 30

Nominal (rated) supply voltage (protective low

voltage)

Current consumption

in measuring mode

A

< 0.9

in start-up mode

A

< 2

Nominal (rated) power consumption

W

< 12