KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Torque Transducer T10FS

Special features

  • Nominal (rated) torques: 100 NVm, 200 NVm, 500 NVm, 1 kNVm, 2 kNVm, 3 kNVm, 5 kNVm, 10 kNVm
  • Nominal speed from 12,000 rpm to 24,000 rpm
  • Low rotor weights
  • Small mass moments of inertia
  • Small outside diameters
  • Non−contacting
  • Option: integrated magnetic or optical speed measuring system

Type

T10FS

Accuracy class

0.05

Torque measuring system

Nominal (rated) torque Mnom

for reference only

N⋅m

100

200

500

1 k

2 k

3 k

5 k

10 k

ft−lb

75

150

375

750

1,500

2,250

3,750

7,500

Nominal sensitivity (range between torque = zero

kHz

5

and nominal (rated) torque)

Frequency output

Voltage output

V

10

Characteristic tolerance (deviation of the actual

output quantity at Mnom from the nominal sensitivity)

Frequency output

%

"0.1

Voltage output

%

"0.2

Output signal at torque = zero

kHz

10

Frequency output

Voltage output

V

0

Nominal output signal

kHz

15 (5 V symmetric1)/12 V asymmetric2))

Frequency output

with positive nominal (rated) torque

with negative nominal (rated) torque

kHz

5 (5 V symmetric1)/12 V asymmetric2))

Voltage output

with positive nominal (rated) torque

V

+10

with negative nominal (rated) torque

V

−10

Load resistance

Frequency output

≥2

Voltage output

≥5

Long−term drift over 48 h

Voltage output

mV

≤"3

Measurement frequency range

Voltage output

Hz

0 ... 1000 (−3 dB)

Group delay time

Frequency output

ms

0.15

Voltage output

ms

0.9

Residual ripple

Voltage output

mV

40 (peak-to-peak)

Temperature influence per 10 K in the nominal

%

< "0.05

temperature range

on the output signal, related to the actual value

of signal span

Frequency output

Voltage output

%

< "0.15

on the zero signal, related to the nom. sensitivity

Frequency output

%

< "0.05 (<"0.03 optional)

Voltage output

%

< "0.15 (<"0.13 optional)

Max. modulation range3)

kHz

4...16

Frequency output

Voltage output

V

−10.5...+10.5 (typ. "11)

Power supply (version KF1)

V

54 "5% (peak-to-peak)

Excitation voltage (square wave)

Release of calibration signal

V

80 " 5 %

Frequency

kHz

approx. 14

Max. current consumption

A

1 (peak-to-peak)

Preamplifier excitation voltage

V

0/0/+15

Preamplifier, max. current consumption

mA

0/0/+25

Power supply (version SF1/SU2)

V (DC)

18 ... 30; asymmetric

Nominal supply voltage (protective low voltage)

Current consumption in measuring mode

A

< 0.9

Current consumption in start-up mode

A

< 2

Nominal (rated) power consumption

W

< 12