Type |
T20WN | |||||||||||
Accuracy class |
0.2 | |||||||||||
Torque measuring system | ||||||||||||
Nominal (rated) torque Mnom |
N⋅m |
0.1 |
0.2 |
0.5 |
1 |
2 |
5 |
10 |
20 |
50 |
100 |
200 |
Nominal (rated) sensitivity (nominal (rated) signal range between torque = zero and nominal (rated) torque)
Sensitivity tolerance (deviation of actual output quantity at Mnom from nominal (rated) signal range) |
V
% |
10
±0.2 | ||||||||||
Output signal at torque = zero |
V |
0±0.2 | ||||||||||
Nominal (rated) output signal at positive nominal (rated) torque at negative nominal (rated) torque Load resistance Long‐term drift over 48 h Cut‐off frequency (‐3 dB) Residual ripple Group delay |
V V MΩ mV Hz mVPP ms |
+10 ‐10 > 1 <±50 200 < 80 < 1.0 | ||||||||||
Temperature effect per 10 K in nominal (rated) temperature range on the output signal, related to the actual value of the signal span on the zero signal, related to the nominal (rated) sensitivity |
% % |
±0.1 ±0.2 | ||||||||||
Power supply Nominal (rated) supply voltage (separated extra‐low voltage (SELV)) Calibration signal triggering Current consumption in measuring mode Nominal (rated) power consumption Max. ripple on supply voltage |
V (DC) V A W
mVpp |
12 (10.8 - 13.2) 5 - 13.2 < 0.2 < 2.4
200 | ||||||||||
Non‐linearity including hysteresis, re lated to nominal (rated) sensitivity |
% |
<±0.1 | ||||||||||
Relative standard deviation of the re peatability per DIN 1319, related to the variation of the output signal |
% |
<±0.05 | ||||||||||
Calibration signal |
V |
+10±0.2% | ||||||||||
Measurement system for rotational speed/angle of rotation | ||||||||||||
Measurement system Pulses per revolution Output signal Minimum rotational speed for sufficient pulse stability Load resistance Group delay
Max. measurable rotational speed |
Number V
min‐1 kΩ μs
min‐1 |
optical 360 5 (asymmetrical); two square wave signals approx. 90° phase shifted 0 >10 < 3 for 1.5 m cable between T20WN and junction box VK20A (without VK20A, the group delay is dependent on the connected impedance / cable & evaluating device) 3000 | ||||||||||
General data | ||||||||||||
EMC Immunity from interference (DIN EN50082‐2) Electromagnetic field Housing Leads Magnetic field Burst ESD |
V/m VPP A/m kV kV |
10 10 100 2/1 4/8 |