KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Torque Transducer T40HS

Special features

  • High speed up to 45000 rpm
  • Digital telemetry system
  • Wide measurement frequency range up to 6 kHz ( -3dB )
  • Without bearings and slip rings
  • Titanium element body
  • Very low rotor weights
  • Very small mass moments of inertia
  • Small outside diameter

Type

T40HS

Accuracy class

0.05

Torque measuring system

Nominal (rated) torque Mnom

N×m

500

1000

2000

3000

Nominal (rated) sensitivity (range between torque = zero and nominal (rated) torque)

Frequency output 10/ 60 / 240 kHz Voltage output

Sensitivity tolerance (deviation of the actual output quantity at Mnom from the nominal sensitivity)

kHz V

%

5 1) / 30 2) / 120 3)

10

± 0.1

Output signal at torque = zero

Frequency output Voltage output

kHz V

10 1) / 60 2)/ 240 3)

0

Output signal at torque = zero Frequency output

with positive nominal (rated) torque with negativ nominal (rated) torque Voltage output

with positive nominal (rated) torque

with negative nominal (rated) torque

kHz kHz

V V

151) / 902) / 3603) ( 5V symmetrical 4) )

51) / 302) / 1203) ( 5V symmetrical 4) )

+10…+12

-10…-12

Load resistance Frequency output Voltage output

Long-term drift over 48 h

Frequency output Voltage output

kW kW

%

%

³ 2

³ 10

< ±0.03

< ±0.03

Measurement frequency range ( -3dB ) Group delay

µs

11) / 32) / 63)

< 4001) / < 2202) / < 1503)

Residual ripple

Voltage output 5)

mV

< 40

Effect of temperature per 10 K in the nominal (rated) temperature range

on the output signal, related to the actual value of signal span

Frequency output Voltage output

on the zero signal, related to the nominal (rated) sensitivity

Frequency output

Voltage output

%

%

%

%

< ±0.05

< ±0.2

< ± 0.05

< ±0.1