KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Torque interface module TIM 40

Special features

  • Connection of T40 torque flange
  • Mounting on support rail per DIN EN 60715
  • Scaling, filtering and zeroing of the torque signal
  • Wide measurement frequency range up to 10 kHz (−3 dB)
  • "10 V and (12"8) mA output signals
  • Ethernet interface with 38125 measured values per second
  • Various Anybus) modules available as accessories

Type

TIM40

Accuracy class

0.05

Energy supply

Nominal (rated) supply voltage Nominal (rated) power consumption

V W

18 ... 30

< 20 W

Transducers that can be connected

HBM’s T40 Torque Flange

Inputs

Max. cable length

m

50

Control signal input shunt

V

> 2.5

Input level "On"

Input level "Off"

V

< 1.5

Max. input voltage

V

36

Max. input current at 24 V

mA

24

Outputs

Frequency output

Nominal (rated) output signal at 10 kHz

60 kHz

240 kHz

Max. modulation range at 10 kHz 60 kHz

240 kHz Output signal in case of error

Level

Max. group delay (scaled, without filter)

kHz kHz kHz

kHz kHz kHz

kHz V

ms

10"5

60"301)

240"120

4 ... 16

24 ... 96

96 ... 384

0

5 symmetrical2)

200

Voltage output

V

−10.0 ... +10.0

Nominal (rated) output signal

Max. modulation range

V

−12.0 ... +12.0

Output signal in case of error

V

12.5 ... 15

Resolution

mV

0.5

Measurement frequency range (−3 dB)

Hz

0 ... 10000

Load resistance

kW

w 5

Long-term drift over 48 h

mV

"5

Current output

mA

12"8

Nominal (rated) output signal

Max. modulation range

mA

3.4 ... 21.6

Output signal in case of error

mA

23 up to 25

Measurement frequency range (−3 dB)

Hz

0 ... 8000

Burden

W

v 500

Digital low-pass filter (Bessel; can be switched off)

Hz

1; 10; 100; 1000; 3000

Low-pass filter TP 1 (−1 dB)

Low-pass filter TP 2 (−1 dB)

Hz

1; 10; 100; 1000; 3000

Effect of temperature per 10 K in the

%

0.05

nominal (rated) temperature range

on the zero signal, related to the nominal (rated)

sensitivity

Voltage output

Current output

%

0.05

Fieldbuses

Ethernet interface Baud rate Connection Protocol

MBit/s

10 and 100 RJ45

TCP/IP, UDP, DHCP

Slots for fieldbus modules

Format Protocol

Number

1

Anybus®-CC

Profibus-DP, CANopen