KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Force Transducer C10

Special features

  • For static and dynamic problems
  • Stainless
  • Accurate (accuracy class 0.03)
  • Various options (double bridge, TEDS, calibration, 50%, various connector options)
  • High light output (>4 mV/V)

For the 100% calibration version (standard version)

Type

C10

Nominal (rated) force

Fnom

kN

2.5

5

10

25

50

100

250

500

1000

Accuracy 1)

Accuracy class

0.03

0.04

0.05

0.06

Relative reproducibility and repeatability errors without rotation

br,g

%

0.025

Hysteresis error (0.4 Fnom)

u0.4

%vI

0.075

0.1

0.125

0.15

%vc

0.03

0.04

0.05

0.06

Non-linearity

dlin

%

0.03

0.04

0.06

Relative creep over 30 min

dcr, F+E

%

0.04

0.025

Effect of eccentricity

dE

%/mm

0.04

Temperature influence on sensitivity

TCC

%/10K

0.015

Effect of temperature on the zero signal

TC0

%/10K

0.0075

Electrical values

Nominal (rated) sensitivity

Cnom

mV/V

2

4

Relative zero signal error

ds,0

%

1

Relative sensitivity error 1)

dc

%

0.1

Input resistance

Ri

Ω

>345

Output resistance

Ro

Ω

280…360

Insulation resistance

Ri

Giga Ω

>2

Operating range of excitation voltage

BU, G

V

0.5…12

Reference excitation voltage

Uref

V

5

Connector

Six wire circuit

Temperature

Reference temperature

Tref

°C

23

Nominal (rated) temperature range

BT, nom

°C

-10…+45

Operating temperature range

BT, G

°C

-30…+85

Storage temperature range

BT, S

°C

-30…+85

Mechanical quantities

Max. operating force

FG

%

120

Limit force

FL

%

120

Breaking force

FB

%

>200

Max. eccentricity

eG

mm

10.2

9.9

9.1

14.1

12

20.6

23.9

Nominal (rated) displacement

snom

mm

0.04

0.06

0.08

0.1

0.12

Fundamental resonance frequency

fG

kHz

4.7

6.5

8.6

5.8

8.2

5.7

7.3

5.9

5.4

Relative permissible oscillatory stress

Frb

%

100

General information

Degree of protection per DIN 60529 with bayonet connector

IP67

with threaded connector

IP64

with a fixed cable

IP67

IP68

Measuring body material

Aluminum

Stainless steel

Cable 2)

Measurement cable with TPE insulation, wires twisted in pairs, 6 or 15 m

Mass

Force Transducer C10 - datasheet PDF, 0.17 Kb