Force Transducer С2

Special features

  • Compressive Force transducer made of rust-resistant materials
  • Low overall height
  • Nominal forces 500 N ... 200 kN
  • Accuracy class 0.1

Type

C2

Nominal forces

Fnom

kN

0.5

1

2

5

10

20

50

100

200

Accuracy class

0.2

0.1

Nominal sensitivity

Cnom

mV/V

2

Rel. tensile/compressive force sensi- tivity variance

dc

%

<±0.2

Rel. deviation from zero

dao

%

<1

Hysteresis

(0.2Fnom to Fnom)

u

%

<0.2

<0.15

Linearity deviation

dlin

%

<0.2

<0.1

Temperature influence on the sensi- tivity per 10 K,

rel. to nominal sensitivity

TKC

%

0.1

Temperature influence on the zero signal per 10 K,

rel. to nominal sensitivity

TK0

%

0.05

Effect of eccentricity per mm

de

%

±0.3

±0.3

±0.2

±0.1

Rel. creep over 30 min

dcrF+E

%

<±0.06

Input resistance

Re

>340

Output resistance

Ra

300 ... 400

Isolation resistance

RIs

GΩ

>2 x 109

Reference excitation voltage

Uref

V

5

Operating range of the excitation voltage

BU,G

V

0.5 ... 12

Nominal temperature range Operating temperature range Storage temperature range

Reference temperature

Bt,nom Bt,G Bt,S

tref

°C [°F]

°C [°F]

°C [°F]

°C [°F]

−10 to +70 [ 14...158]

−30 to +85 (120)2) [−22...185(248)2)]

−50 to +85 [ −58...185]

+23 [ 73.4]

Max. operational force Limit force

Breaking force

Static lateral limit force1)

(FG)

(FL)

(FB)

(FQ)

%

%

%

%

130

130

150

150

>300

50

Nominal displacement

Snom

mm

<0.1

<0.06

Fundamental resonance frequency

fG

kHz

4.4

8.7

9.7

18.5

19.3

13

14

13

14

Weight

kg

0.4

1.8

1.8

3

3

Rel. permissible vibration stress

Frb

%

100

Protection to DIN EN 60529

IP67 (IP68)3)

Cable length, six-wire technique

m

3

6

12

Force Transducer С2 - datasheet PDF, 0.33 Kb