Force Transducer С6A

Special features

  • Compressive force transducer
  • Nominal forces 200 kN ... 5 MN 
  • Continuous inner bore for nominal forces from 200 kN to 2 MN 
  • Rust-resistant version for 200 kN and 500 kN nominal forces 
  • Extensive mounting accessories

Type

C6A

Accuracy class

0.5

Nominal force

Fnom

MN

200 kN

500 kN

1 MN

2 MN

5 MN

Nominal sensitivity

Cnom

mV/V

2

Relative sensitivity deviation2)

when used with hardened pressure plates

when used with load button ZL and pendle bearing EPO3 when used with spherical cap ZK

Relative zero signal deviation

Relative range of inversion (0.5Fnom)

Linearity deviation 2)

when used with hardened pressure plates

when used with load button ZL and pendle bearing EPO3 when used with spherical cap ZK

Effect of temperature on sensitivity / 10 K by reference to nominal

sensitivity

Effect of temperature on zero signal / 10 K by reference to nominal sensitivity

Creep over 30 min, in nominal temperature range 1)

dc

ds,o u dlin

TKc TK0

dcrF+E

%

%

%

%

%

%

%

%

%

%

%

< ±2.5

< ±0.5

< ±2.5 < ±4

<±1

<±0.5

< ±0.5

<1

< ±0.8

< ±1 < ±0.5

< ±0.5 < ±0.5

< ±1 < ±0.5

< ±0.1

< ±0.05

< ±0.06

Input resistance at reference temperature Output resistance at reference temperature

Isolation resistance at test voltage 100 V

Re Ra

Ris

GΩ

> 345

356 ±1.5

>5x 109

Reference excitation voltage

Operating range of the excitation voltage

Uref BU,GT

V

V

5

0.5 ... 12

Reference temperature Nominal temperature range Operating temperature range Storage temperature range

tref Bt,nom Bt,G

Bt,S

°C

°C

°C

°C

+23

ï10...+70

ï30...+85 ï50...+100

Maximum operating force 1)

FG

%

150

Limit force 1)

Breaking force 1)

when used with hardened pressure plates

when used with load button ZL and pendle bearing EPO3 when used with spherical cap ZK

FL FB

%

%

%

%

150

>300

>300

>200

>200

>200

Static lateral limit force 1)

when used with hardened pressure plates

when used with load button ZL and pendle bearing EPO3 when used with spherical cap ZK

Permissible vibration amplitude 1) to DIN 50 100

FQ

Frb

%

%

%

%

20

20 10

10

70

Nominal displacement without mounting accessories ( ±15 %)

Natural frequency without coupled ground and without mounting accessories

Weight, without cable

Snom fG

mm kHz

kg

0.07

4.5

1.4

0.08

8

1.7

0.09

6

10.8

0.11

7.5

12.2

0.26

4.3

33

Degree of protection to DIN EN 60 529

Cable length, 6ïwire connection

m

IP 67

6