KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Force Transducer U10S

Special features

  • Tensile/compressive force transducer
  • For dynamic and static applications
  • High endurance at high vibration bandwidths
  • Electronic bending moment adjustment
  • Double bridge version option
  • Rust-resistant materials

Nominal (rated) force

Fnom

kN

1.25

2.5

5

12.5

25

50

125

225

450

Nominal (rated) sensitivity

Cnom

mV/V

1 ¼ 1.5 1)

2 ¼ 2.5 1)

Accuracy class

0.03

0.04

0.05

0.06

Relative repeatability error in an unmodified mounting position

brg

%

0.025

Relative zero signal error

ds, 0

%

1

Relative reversibility error 2)

(at 0.4·Fnom)

n0.4

%vl

%vc

< 0.075

0.03

< 0.1

0.04

< 0.125

0.05

< 0.125

0.05

Relative linearity error

dlin

%

<±0.03

<±0.04

<±0.06

Relative creep over 30min

dcrf+E

%

<±0.04

<±0.025

Effect of temperature on sensitivity/10K

TKC

%

<±0.015

Temperature effect on the zero signal/10K

TK0

%

<±0.015

Bending moment influence

(at10%·Fnom·10mm)

dQ

%

<0.01

Output resistance

Ro

W

280 ¼ 360

Input resistance

Ri

W

> 345

Insulation resistance

Ris

GW

> 2

Reference excitation voltage

Uref

V

5

Operating range of excitation voltage

BU, G

V

0.5 to 12

Reference temperature

Tref

°C [°F]

+23 [73.4]

Nominal (rated) temp. range

BT,nom

10 ¼ +45 [+14 ¼ +113]

Operating temperature range

BT, G

30 ¼ +85 [ 22 ¼ +185]

Storage temperature range

BT, S

30 ¼ +85 [ 22 ¼ +185]

Max. operating force

(FG)

% v.

Fnom

240

Breaking force

(FB)

> 400

Static lateral limit force 3)

(FQ)

100

Limit bending moment 5)

Mb perm

N·m

30

60

125

315

635

1270

3175

5146

10290

Limit torque 5)

ML

N·m

30

60

125

315

635 4)

1270

3175

5146

10290

Nominal (rated) displacement

snom

mm

0.02

0.03

0.04

0.05

0.06

Fundamental resonance freq.

fG

kHz

4.5

5.9

9.3

6.6

9.2

6.5

8.1

6.5

5.8

Rigidity

F/S

105

N/mm

0.625

1.25

2.5

4.17

8.33

16.7

31.3

48.8

79.7

Permissible vibrational stress

(Vibration bandwidth per DIN

50100)

Frb

% v.

Fnom

200

Weight (without cable)

With adapter

Without adapter

kg lbs kg lbs

1.2

2.65

0.5

1.1

3

6.61

1.3

2.87

10

22.05

5

11.02

23

50.71

11

24.25

60

132.28

28

61.73

Immunity from interference

(EN 61326 1, Table A.1)

Electromagnetic field (AM) Magnetic field

Electrostatic discharge (ESD)

Contact discharge

Air discharge

Burst (rapid transients)

Surge (impulse voltages)

Grid bound interferences (AM)

V/m A/m

kV kV kV kV V

Industrial environment

10

30

4

8

1

1

3

Mechanical shock

(Test severity level IEC 68 2 29 1987)

Number Duration Acceleration

n ms m/s2

1000

3

1000

Force Transducer U10S - datasheet PDF, 0.55 Kb