Force transducer type |
|
|
U2B | ||||||||
Nominal (rated) force |
Fnom |
N |
500 |
|
|
|
|
|
|
|
|
kN |
|
1 |
2 |
5 |
10 |
20 |
50 |
100 |
200 | ||
Accuracy | |||||||||||
Accuracy class |
|
|
0.2 |
0.1 | |||||||
Relative reproducibility and repeatability errors without rotation |
brg |
% |
0.1 | ||||||||
Rel. reversibility error (0.5 * Fnom) |
V0.5 |
% |
<0.2 |
0.15 | |||||||
Non-linearity |
dlin |
% |
<0.2 |
0.1 | |||||||
Creep upon loading (30 min) |
dcr, F+ E |
% |
0.06 | ||||||||
Effect of the bending moment (10% Fnom * 10 mm) |
dMb |
% |
0.05 | ||||||||
Effect of lateral forces (10% Fnom) |
dQ |
% |
0.1 | ||||||||
Temperature effect on sensitivity |
TCS |
% / 10 K |
0.1 | ||||||||
Temperature effect on zero point |
TC0 |
% / 10 K |
0.05 | ||||||||
Characteristic electrical values | |||||||||||
Nominal (rated) sensitivity |
Cnom |
mV/V |
2 | ||||||||
Relative zero signal error |
ds,0 |
% |
1 | ||||||||
Sensitivity error, tension |
dC |
% |
0.2 | ||||||||
Sensitivity error, tension/compres- sion |
dZD |
% |
1.5 |
0.5 | |||||||
Input resistance |
Ri |
Ω |
>345 | ||||||||
Output resistance |
Ro |
Ω |
300...400 | ||||||||
Insulation resistance |
Ris |
Ω |
2⋅109 | ||||||||
Operating range of the excitation voltage |
BU,G |
V |
0.5...12 | ||||||||
Reference excitation voltage |
Uref |
V |
5 | ||||||||
Temperature | |||||||||||
Reference temperature |
Tref |
°C |
+23 | ||||||||
Nominal (rated) temperature range |
BT,no m |
°C |
-10 ... +85 | ||||||||
Operating temperature range |
Bt,G |
°C |
-30 ... +85 | ||||||||
Storage temperature range |
BT,S |
°C |
-50 ... +85 | ||||||||
Characteristic mechanical quantities | |||||||||||
Maximum operating force |
FG |
% of Fnom |
130 |
150 | |||||||
Limit force |
FL |
>130 |
>150 | ||||||||
Breaking force |
FB |
>300 | |||||||||
Limit torque (when loading with nominal (rated) force) |
MG |
Nm |
46.8 |
63.0 |
63.0 |
60.0 |
108.0 |
340.0 |
620.0 |
2430.0 |
5125.0 |
Limit bending moment (when loading with nominal (rated) force) |
Mb max |
Nm |
2.9 |
12.8 |
19.0 |
24.0 |
49.0 |
223.0 |
380.0 |
1463.0 |
2880.0 |
Static lateral limit force (when loading with nominal (rated) force) |
FQ |
% of Fnom |
25.0 |
52.0 |
36.0 |
18.0 |
25.0 |
35.0 |
19.0 |
25.0 |
19.0 |
Nominal (rated) displacement ±15% |
Snom |
mm |
0.058 |
0.056 |
0.048 |
0.047 |
0.047 |
0.065 |
0.082 |
0.09 |
0.12 |
Fundamental frequency |
fG |
kHz |
4 |
6 |
8.7 |
14 |
17.5 |
8 |
8.5 |
6 |
5.6 |
Rel. permissible vibrational stress |
Frb |
% of Fnom |
100 |
160 | |||||||
General information | |||||||||||
Degree of protection per DIN EN 60529 1) |
IP67 | ||||||||||
Spring element material |
Stainless steel | ||||||||||
SG protection |
Hermetically-welded measuring body | ||||||||||
Cable |
6-wire, polyethylene insulated | ||||||||||
Cable length |
As requested by the customer | ||||||||||
Weight |
kg |
0.8 |
2.9 |
4.3 |
10.7 |
15.9 |
Force Transducer U2B - datasheet | PDF, 0.14 Kb |