KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Force Transducer U93

Special features

  • Tensile/compressive force transducer
  • Simple installation thanks to flange connection on both sides
  • Integrated TEDS electronic data sheet
  • Compact
  • Robust
  • Stainless steel transducer
  • Suitable for cable drag chains

Type

U93

Data as per VDI 2638

Nominal (rated) force

Fnom

kN

1

2

5

10

20

50

Nominal (rated) sensitivity

Relative sensitivity error (compression) Relative zero signal error

Rel. reversibility error (0.5 Fnom)

Cnom dc

ds,o

ν0.5

mV/V

%

mV/V

%

0.5

1

0.5

1

0.5

1

<±0.5

<±0.075

<±0.5

Relative linearity error

dlin

%

<±0.5

Effect of temperature on sensitivity/ 10 K,

related to nominal (rated) sensitivity

Effect of temperature on zero signal/ 10 K,

related to nominal (rated) sensitivity

Relative creep over 30 min

TKC

TK0

dcrF+E

%

%

%

<±0.5

<±0.8 <±0.5 <±0.8 <±0.5 <±0.8 <±0.5

<±0.2

Effect of lateral forces (lateral force 10% Fnom)1)

dQ

%

< 0,2

< 0,5

< 0,4

Effect of eccentricity per mm

dE

%

< 0.07

< 0.03

< 0.12

Input resistance Output resistance

Isolation resistance

Ri Ro

Ris

Ω

Ω

Ω

> 295

230−350

>1⋅109

Reference excitation voltage

Operating range of the excitation voltage

Uref

BU,G

V

V

5

0.5...12

Nominal temperature range Operating temperature range Storage temperature range

Reference temperature

Bt,nom Bt,G Bt,S

tref

°C

°C

°C

°C

−10...+70

−30...+85

−50...+85

+23

Max. operating force

Breaking force

(FG)

(FB)

%

%

180

> 400

> 300

> 300

Lateral force limit 1)

Permissible force application eccentricity

(FQ)

eG

%

mm

100

1.5

80

3

40

6

Nominal (rated) displacement (±15%)

Snom

mm

0.01

0.02

0.02

0.04

0.01

0.03

Fundamental resonance frequency

fG

kHz

7.9

11.7

10.3

Weight with cable, approx.

g

200

600

Relative permissible oscillatory stress

Frb

%

15 0

Cable connection, six−wire connection

3 m cable length; outside diameter 4 mm; 6 x 0.08 mm2; polyurethane sheath; min. bending radius R10

Degree of protection per DIN 60529

IP67

Transducer identification

TEDS, as per IEEE 1451.4

Force Transducer U93 - datasheet PDF, 0.09 Kb