Type |
U93 | |||||||
Data as per VDI 2638 |
|
| ||||||
Nominal (rated) force |
Fnom |
kN |
1 |
2 |
5 |
10 |
20 |
50 |
Nominal (rated) sensitivity
Relative sensitivity error (compression) Relative zero signal error Rel. reversibility error (0.5 Fnom) |
Cnom dc ds,o ν0.5 |
mV/V
% mV/V
% |
0.5 |
1 |
0.5 |
1 |
0.5 |
1 |
<±0.5 <±0.075
<±0.5 | ||||||||
Relative linearity error |
dlin |
% |
<±0.5 | |||||
Effect of temperature on sensitivity/ 10 K, related to nominal (rated) sensitivity
Effect of temperature on zero signal/ 10 K, related to nominal (rated) sensitivity
Relative creep over 30 min |
TKC
TK0
dcrF+E |
%
%
% |
<±0.5
<±0.8 <±0.5 <±0.8 <±0.5 <±0.8 <±0.5
<±0.2 | |||||
Effect of lateral forces (lateral force 10% Fnom)1) |
dQ |
% |
< 0,2 |
< 0,5 |
< 0,4 | |||
Effect of eccentricity per mm |
dE |
% |
< 0.07 |
< 0.03 |
< 0.12 | |||
Input resistance Output resistance Isolation resistance |
Ri Ro Ris |
Ω Ω Ω |
> 295
230−350 >1⋅109 | |||||
Reference excitation voltage
Operating range of the excitation voltage |
Uref BU,G |
V
V |
5
0.5...12 | |||||
Nominal temperature range Operating temperature range Storage temperature range Reference temperature |
Bt,nom Bt,G Bt,S tref |
°C °C °C °C |
−10...+70
−30...+85
−50...+85
+23 | |||||
Max. operating force
Breaking force |
(FG) (FB) |
%
% |
180 | |||||
> 400 |
> 300 |
> 300 | ||||||
Lateral force limit 1)
Permissible force application eccentricity |
(FQ) eG |
%
mm |
100
1.5 |
80
3 |
40
6 | |||
Nominal (rated) displacement (±15%) |
Snom |
mm |
0.01 |
0.02 |
0.02 |
0.04 |
0.01 |
0.03 |
Fundamental resonance frequency |
fG |
kHz |
7.9 |
11.7 |
10.3 | |||
Weight with cable, approx. |
|
g |
200 |
600 | ||||
Relative permissible oscillatory stress |
Frb |
% |
15 0 | |||||
Cable connection, six−wire connection |
3 m cable length; outside diameter 4 mm; 6 x 0.08 mm2; polyurethane sheath; min. bending radius R10 | |||||||
Degree of protection per DIN 60529 |
IP67 | |||||||
Transducer identification |
TEDS, as per IEEE 1451.4 |
Force Transducer U93 - datasheet | PDF, 0.09 Kb |