Type |
BU18 / 3 MN | ||
Data per VDI 2638 and ISO 376 |
| ||
Nominal (rated) force |
Fnom |
kN |
3000 |
Class under ISO 376 (0.2 Fnom to Fnom) |
001) | ||
Nominal (rated) sensitivity |
Cnom |
mV/V |
2 |
Rel. sensitivity deviation |
dc |
% |
< ±0,1 |
Rel. deviation from zero |
ds,o |
mV/V |
< ±1 |
Relative reproducibility and repeatability errors |
b’ |
% |
< ±0,015 |
(0.2Fnom to Fnom) for: | |||
a constant mounting position | |||
varying mounting positions |
b |
% |
< ±0,04 |
Relative deviation from fitting curve (0.2Fnom to Fnom) |
fc |
% |
< ±0,02 |
Relative zero error (zero signal return) |
fo |
% |
< ±0,008 |
Relative reversibility error (0.2Fnom to Fnom) |
ν |
% |
< ±0,06 |
Relative linearity error |
dlin |
% |
< ±0,025 |
Effect of temperature on sensitivity, per 10 K, related |
TKc |
% |
< ±0,01 |
to nominal (rated) sensitivity | |||
Effect of temperature on zero signal per 10 K, related |
|
|
|
to nominal (rated) sensitivity |
TK0 |
% |
< ±0,01 |
Relative creep over 30 min |
dcrF+E |
% |
< ±0,03 |
Effect of lateral forces (lateral force 10% Fnom) |
dQ |
% |
< 0,1 |
Effect of eccentricity per mm |
dE |
% |
< 0,02 |
Input resistance |
Ri |
Ω |
4450 ± 100 |
Output resistance |
Ro |
Ω |
4010 ± 2 |
Insulation resistance |
Ris |
Ω |
> 50 x 109 |
Reference excitation voltage |
Uref |
V |
5 |
Operating range of the excitation voltage |
BU,G |
V |
5...30 |
Carrier frequency of excitation voltage |
Hz |
< 600 | |
Nominal (rated) temperature range |
Bt,nom |
°C |
+10 ... +40 |
Operating temperature range |
Bt,G |
°C |
−30 ... +80 |
Storage temperature range |
Bt,S |
°C |
−50 ... +85 |
Reference temperature |
tref |
°C |
+22 |
Max. operating force |
(FG) |
% |
170 |
Limit force |
(FL) |
% |
170 |
Breaking force |
(FB) |
% |
400 |
Permissible horizontal displacement of top plate |
eG |
mm |
<±2 |
Nominal (rated) displacement |
Snom |
mm |
0.45 |
Weight (with VKK, without carrying case) |
|
kg |
107 |
Degree of protection per DIN 60529 |
IP53 |
Force Transducer BU18 - datasheet | PDF, 0.15 Kb |