KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Coated strain measuring fiber OptiMet-PKF 2&4

Special features

  • Optical fiber with fiber Bragg gratings
  • Two or four fiber Bragg gratings
  • Test version to OptiMet‐PKF with reduced number of Bragg gratings
  • Simple installation
  • Robust, resistant to most chemicals
  • Insensitive to electromagnetic interferences
  • Application in Ex‐areas possible

Design

OptiMet‐OMF glass fiber embedded in coating with 2 or 4 Bragg gratings

Core diameter of glass fiber, approx.

μm

6

Diameter of fiber cladding, approx.

μm

125

Outer diameter of OMF fiber, approx.

μm

195

Outer diameter with coating, approx.

μm

700 ±50

Connection (plug)

FC/APC

Available Bragg wavelengths 2)

nm

1515 … 1585

Bragg wavelength spacing tolerance

nm

±1

Gage factor

0.79

Gage factor tolerance

%

±2

Reference temperature

°C

23

Operating temperature range

°C

-40 ¼ +140

Storage temperature range

°C

-40 ¼ +140

Thermal cross sensitivity (TCS)

thermal contributing of sensor to strain signal

μm/m/°C

7.1

Tolerance of thermal cross sensitivity (TCS)

μm/m/°C

±1

Maximum elongation

μm/m

7,000 (0.7%)

at reference temperature when using X120 adhesive

Strain in positive direction

Strain in negative direction

μm/m

7,000 (0.7%)

Fatigue life

at reference temperature when using X120 adhesive Achieved no. of load cycles Lw on steel measuring body at

alternating strain εw = ±1000 μm/m and variation of zero point

<30 μm/m

>> 107 (aborted after 107 load cycles)

Smallest bend radius at reference temperature

mm

10

Preferred bonding material

X120

Coated strain measuring fiber OptiMet-PKF 2&4 - technical parameters PDF, 0.27 Kb