Type |
MVD2510 | |||
Mains/supply voltage |
V |
115/230; +6 %; −10 % | ||
|
Hz |
48...60 | ||
Power consumption, max. |
VA |
8 | ||
Fusible-link fuse (slow blow) |
mA |
T 125 mA L (115 V) / T 63 mA L (230 V) | ||
DC amplifier |
VB |
±2.5 V | ||
Bridge excitation voltage (±5 %) | ||||
Transducers that can be connected |
|
| ||
Strain-gauge full bridges |
Ω |
80...5000 | ||
Permissible cable length between transducer and |
m |
500 | ||
amplifier |
|
| ||
Measuring ranges, adjust. (-1 dB) |
Hz |
0.05...5 | ||
Measuring range |
mV/V |
0.2...3.8 | ||
Bridge balance range |
mV/V |
±3.8 | ||
Measuring frequency range |
|
Nom. val. |
-1 dB -3 dB Phase del Rise |
Overshoot |
Butterworth low pass (2nd order) |
fc |
(Hz) (Hz) . time |
(%) | |
(Hz) |
4.9 6.9 (ms) (ms) |
5 | ||
5 |
2.0 3.6 100 54 |
− | ||
2 |
1.0 1.8 140 100 |
− | ||
1 |
0.48 0.86 200 196 |
− | ||
0.5 |
0.21 0.39 290 406 |
− | ||
0.2 |
0.105 0.195 580 900 |
− | ||
0.1 |
0.050 0.099 1070 1800 |
− | ||
0.05 |
2140 3600 |
| ||
Noise voltage (typical) without filter with filter Max. permissible comm. mode volt. Common-mode rejection Max. permissible voltage on input Linearity deviation Long-term drift over 48 hours After 15 minutes warm-up Effect of 10 K ambient temperature change Zero point Sensitivity |
μV/Vpp μV/Vpp V dB V % μV/V μV/V % |
<0.4 <0.2 ±2 >120 ±5 <0.02
<0.3
< 0.4 < 0.05 | ||
Analogue output Impressed voltage Permissible load resistance, min. Internal resistance, max. Impressed current Permissible load resistance, max. Internal resistance, min. Analogue output can represent gross and net val- ues Noise voltage Residual carrier (300 Hz) Long-term drift over 48 hours (After 30 minutes warm−up) Effect of 10 K ambient temperature change (effect additional to digital value) Zero point Sensitivity |
V kΩ Ω mA Ω kΩ
mVSS mVSS
mV
mV % |
±10 V 5 1.5 ±20; 4...20 500 100
10, typ. 5
< 3
< 5 < 0.1 |
Amplifier for panel mounting MVD2510 - datasheet | PDF, 0.14 Kb |