KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Digital amplifier digiCLIP DF31DP

Special features

  • Digital amplifier for industrial automation tasks and production process monitoring
  • 600 Hz CF measurement technology with TEDS sensor detection for SG full bridges
  • Fast peak and limit value monitoring and digital inputs/outputs
  • Accuracy class, typically 0.05%
  • Modular mounting on a DIN EN 60715 type DIN rail (IEC 60715)
  • Standardized Profibus DP interface with DPV1 functionality for parameterization and backup

digiCLIP

Accuracy class (at UB = 2.5 V and UB = 1 V); after autocalibration

0.05 type.

1.1 in an industrial environment as per EN 61326

1.2 in the 10 mV/V measuring range

Power supply

Supply voltage,

Overvoltage and reverse polarity protection

VDC

24

Isolation voltage

Potential separation between the supply bus and transducer connection, functional separation, must not be considered for safety aspects

VDC

500

Permissible supply voltage range

V

18 ... 30

Influence of supply voltage on accuracy

%/V

< 0.001

Power consumption, max.; incl. transducer

W

3

Amplifier

Carrier frequency rectangle

Hz

600 (591.9 Hz ±100 ppm)

Synchronization

when several interconnected modules are used, the carrier frequency is synchronized automatically

Bridge excitation voltage UB,

Peak−to−peak (±10%)

V

2,5

1,0

Measuring range

mV/V

±4

±10

Connectable transducers

SG full bridge

ohms

80 ... 5000

Connection technique

4 or 6−wire circuitry with single-wire open-circuit monitoring

Permissible cable length between transducer and amplifier, max.

m

100

Input resistance

MOhm

>5

Measurement frequency range, adjustable (−3dB) (see filter table)

Hz

0.05 ... 225

Filter characteristics

Bessel, 4th order

Noise voltage relative to input, for UB = 2.5 V, typical

µV/V

1.0 (at filter frequenzy 100 Hz)

0.05 (at filter frequenzy 1 Hz)

Influence of ambient temperature for change of 10 K

on the zero point (TK0) on sensitivity (TKC)

µV/V

%

0.1

0.05 f.s.

Linearity deviation

% f.s.

0.005

Long-term drift, without AutoCal

%

<0.001 (within 48 h)

Communication interface

Number of devices on the bus, max. Address settings

Protocol

Bit rate, max. Line length, max.

Profibus ID number Parameterization (asynchronous) Profibus connection

MBit/s m

97

3 − 99 (adjustable via frontal rotary switch)

Profibus DP slave, to DIN 19245−2, DPV1 Class 1 and Class 2; available at www.profibus.org

12 1,5 0,5 0,187 0,093

100 200 400 1000 1200

096D (hex)

to Profibus DPV1 standard

Side connector terminal; electrically isolated from supply and measurement ground

Option: DF001: 9−pin Sub-D (DIN19245)

Signal conditioning

A/D converter

Delta-Sigma, 24−bit

Scaling accuracy

bits

32

Sampling rate

1/s

1184

Digital amplifier digiCLIP DF31DP - datasheet PDF, 0.4 Kb