Accuracy class |
0.03 | |
Supply voltage |
VDC |
24; Potential separation from measuring system (typ. 500 VDC) |
Permitted supply voltage range |
VDC |
18...30 |
Power consumption, max. |
W |
9 |
Amplifier |
|
|
Carrier frequency (±1 %) |
Hz |
600 |
Bridge excitation voltage UB (±5 %) |
Vrms |
5 2.51) |
Transducers that can be connected S.G full bridge |
Ω |
60...5000 |
Permitted length of cable between transducer and amplifier, max. |
m |
500 |
Maximum permitted common-mode voltage Common-mode rejection 0...60 Hz 0...600 Hz Linearity deviation (typically), range 2 mV/V
Noise voltage, when UB=5 V, relative to the input, measuring range ±3 mV/V
0...1 Hz 0...20 Hz Measurement frequency range, adjustable (-1dB) Max. display resolution Min. display resolution Input sensitivity Ranges (selectable via DIP switch) at UB=5 V at UB=2.5 V Low pass filter
Effect of change in operating voltage in the specified range, relative to full scale on zero point on sensitivity |
V
dB dB %
μV/VPP μV/VPP Hz
mV/V mV/V mV/V Hz
% % |
±5
>120 >94 0.02
0.05 0.2 0.05 ... 20
999 999 digits at 6.67 % of amplifier input range 10 digits at 100 % of amplifier input range 0.15 ... 3
0.15 ... 3 0.3 ... 6
0.05 ... 20 Adjustable in steps of 0.05 to 20 Hz (Bessel and Butterworth filter characteristics)
<0.01 <0.01 |
Effect of change in ambient temperature of 10 K on zero point on sensitivity Long-term drift over 48 hours measuring range 3 mV/V (30 minutes after switching on) |
μV/V %
μV/V |
with Autocal without Autocal 0.1 0.5 0.01 typ.; 0.02 max. 0.05
<0.2 <2 |
Specifications for single-channel module: MP50
Accuracy class |
0.1 | |
Supply voltage |
VDC |
24; Potential separation from measuring system (typ. 500 VDC) |
Permitted supply voltage range |
VDC |
18...30 |
Power consumption, max. |
W |
9 |
Amplifier |
|
|
Carrier frequency (±1 %) |
kHz |
4.8 |
Excitation voltage UB (±5 %) |
Vrms |
5 2.5 1 |
Transducers that can be connected |
Ω |
220...5000 110...5000 60...5000 |
Strain gauge half and full bridges | ||
Inductive half and full bridges, LVDTs |
mH |
8...160 4...160 2...160 |
Permitted length of cable between transducer and amplifier, max. |
m |
500 |
Maximum permitted common−mode voltage Common−mode rejection 0...500 Hz 0...4800 Hz Maximum differential voltage Linearity deviation (typical)
Noise voltage, at UB=5 V, by reference to input
0...10 Hz 0...500 Hz Measurement frequency range, adjustable (-1 dB) Max. display resolution Min. display resolution |
V
dB dB mV %
μV/VSS μV/VSS Hz |
±5
120 72 ±30 0.025
Range (mV/V) 3 50 500 |
0.2 3 30 1.5 25 250 0.05...500 999 999 digits at 6.67 % of amplifier input range 10 digits at 100 % of amplifier input range | ||
Input sensitivities Ranges (selectable via DIP switch) at UB=5 V at UB=2.5 V at UB=1 V Low pass filter
Effect of change in operating voltage in the specified range, relative to full scale on zero point on sensitivity |
mV/V mV/V mV/V
% % |
low middle high
0.15...3 2.5...50 25...500 0.3...6 5...100 50...1000 0.75...15 12.5...250 125...2500 Adjustable in steps of 0.05 to 500 Hz (Bessel and Butterworth filter characteristics)
< 0.01 < 0.01 |
Effect of 10 K change in ambient temperature of 10 K, |
μV/V |
3 mV/V 50 mV/V 500 mV/V |
at UB=5 V | ||
on zero point full bridge |
1 10 100 | |
on zero point half bridge |
μV/V |
10 20 100 |
on sensitivity |
% |
0.05 0.05 0.05 |
Long-term drift over 48 hours |
|
|
Range 3 mV/V (30 minutes after switching on) |
μV/V |
1 |
Specifications for single-channel module: MP60
Accuracy class |
0.05 | |
Supply voltage |
VDC |
24;potential separation from measuring system (typ. 500 VDC) |
Permitted supply voltage range |
VDC |
18...30 |
Power consumption, max. |
W |
9 |
Amplifier |
|
|
Transducers that can be connected |
|
HBM torque transducer type series T10F-KF1, T4WAS3, T30FN − T34FN in conjunction with MP07; T10F-SF1 and SU2 can be connected directly Incremental transducer Frequency signal sources |
Input Cable length |
m |
Differ. inputs for symmetrical and asymmetrical freq. signals 70 |
Input level1) |
V |
−5 ... +5 |
Each line to measurement earth | ||
Signal amplitude |
Vpp |
>1 |
Hysteresis, switch over threshold selectable in steps |
V |
0.25 |
Trigger level |
V |
±5 (adjustable in steps of 250 mV) |
Input impedance2) (input level −5 V... +5 V) |
kΩ |
>100 |
Input filter |
|
Glitch filter, disconnectable |
Detection of direction of rotation |
|
via additional ±90 o phase−shifted frequency signal |
Frequency quadrupling |
kHz |
connectable |
Input range |
| |
Frequency measurement |
0.0001...1 | |
|
kHz |
0.001...10 |
|
kHz |
0.02...20 |
|
kHz |
0.01...100 |
|
kHz |
0.1...1000 |
Pulse counting |
pul. |
0...999999 |
0...5X106 | ||
0...1X109 (Kilo−Pulses) | ||
Resolution (for frequency measurement) |
% |
0.01 of measurement value |
Maximum pulse rate |
pul./s |
1 000 000 |
Linearity deviation |
% |
0.01 |
Low-pass filter
Sampling rate with filter deactivated |
Hz
1/s |
disconnectable and adjustable in steps of 0.05 to 500 Hz (Bessel and Butterworth filter characteristics) 4800 |
Calibration accuracy |
% |
0.01 |
Long-term drift over 48 hours |
% |
< 0.01 |
30 minutes after switching on | ||
Effect of change in operating voltage in the specified |
|
|
range (in relation to full scale) |
|
|
on sensitivy |
% |
0.01 |
Effect of 10 K change in ambient temperature |
|
|
on sensitivy |
% |
0.01 |
General specifications for single-channel modules: MP30, MP55, MP60
Analog output Impressed voltage Permitted load resistance, min. Internal resistance. max. Impressed current Permitted load resistance, max. Internal resistance. min. The analog output may show gross, net, positive and negative peaks and peak-to-peak values. Analog output scale range, min. Analog output scale range, max. Output noise voltage, typically Long-term drift over 48 hours (30 minutes after switching on)
Effect of 10 K change in ambient temperature (in addition to the digital value) on zero point voltage current on sensitivity |
V kΩ Ω mA Ω kΩ
mVnoise mV
mV μA % |
±10 10 10 ±20; 4...20 500 100
0.17 V (0.5 V1)) at 100 % of amplifier input range 10 V at 3.67 % (1 %1)) of amplifier input range 10
< 3
3 6 0,05 |
Additional functions Limit switches Number Reference level Hysteresis Adjustment accuracy Response time |
% % ms |
4 Gross, net, peak values 0...100 0.0033 1 |
Peak-value stores |
ms |
2 |
Number | ||
Function |
Positive, negative, peak-to-peak | |
Updating time |
1 | |
Clear peak value store |
ms |
2 |
Hold current sample/peak value |
ms |
2 |
Discharge rate of the envelope |
Physic. |
0 to 99 99 99 |
unit/s | ||
Control outputs Number Nominal voltage, external power supply Permitted supply voltage range Output current, max. Short-circuit current, typical Short-circuit period Isolation voltage, typical Functions: Output 1
Output 2
Output 3, output 4 Control inputs Number Functions Input voltage range, LOW Input voltage range, HIGH Input current, typical, HIGH level = 24 V Isolation voltage, typical |
V V A A
Vrms
V V mA Vrms |
4 24 18...30 0.5 / 0.11) 0.8 / 0.21) unlimited 500
selectable: LIV1 − LIV4, error2), idle, signal F11) (typically up to 300 kHz), counting pulse (1.6 μs width)1) selectable: LIV1 − LIV4, error2), idle, signal F21) (typically up to 300 kHz ), direction of rotation1) selectable: LIV1 − LIV4, error2)
4 tare, zero setting, peak-value/current value, parameter set selection, shunt1) 0...5 10...30 12 |
500 | ||
Parameter memory (EEPROM) |
|
4 ( plus factory setting) |
Electronics for industrial measurement PME - datasheet | PDF, 0.3 Kb |