Type |
MVD2555 | ||
Accuracy class |
0.1 | ||
Mains connection/supply voltage |
V |
115/230, +6 %; -14 %; | |
Power consumption, max. Fusible link (slow‐blow) |
Hz VA mA |
48 ¼ 60 8 T 125 mA L (115 V) / T 63 mA L (230 V) | |
Amplifier
Carrier frequency Bridge excitation voltage UB (±5 %) Measuring transducer Strain‐gauge half and full bridge Inductive half and full bridge, LVDT
Perm. cable length between transducer and amplifier |
Hz Vrms
W mH
m |
|
|
4800±0.32 1 or 2.5 | |||
UB = 1 Vrms |
UB = 2.5 Vrms | ||
40 ¼ 5000 |
80 ¼ 5000 | ||
6 ¼ 19 |
2.5 ¼ 20 | ||
max. 500 |
max. 500 | ||
Measuring ranges, adjustable (‐1 dB) Measuring range (Hardware) Measuring ranges UB=2.5 V UB=1 V Bridge balance range UB=2.5 V UB=1 V Noise voltage1) 0...200 Hz 0...1.25 Hz |
Hz
mV/V mV/V mV/V mV/V mV/Vpp mV/Vpp |
0.05 ¼ 1000 low medium high 0.2 ¼ 4 2 ¼ 40 20 ¼ 400 0.5 ¼ 10 5 ¼ 100 50 ¼ 1000
±4 ±40 ±400 ±10 ±100 ±1000
0.5 1 10 0.025 0.1 1 | |
Effect of a 10 K change of the ambient temperature1) on |
% |
0.04/0.1 0.04/0.1 0.04/0,1 | |
the digital signal (with autocalibration on/off) | |||
Sensitivity | |||
Zero point |
mV/V |
0.2/2 2/20 20/200 | |
Measuring frequency range |
|
Nom. val. fc ‐1 dB ‐3 dB Phase del. Rise time Overshoot | |
Butterworth low pass |
(Hz) (Hz) (Hz) (ms) (ms) (%) | ||
|
1000 1010 1165 0.66 0.35 12 | ||
|
500 485 580 1.1 0.7 12 | ||
|
200 245 290 1.7 1.3 11 | ||
|
80 78 98 4.3 3.8 10 | ||
|
40 38 50 7.1 7.3 8 | ||
|
20 19 26 12 14 7 | ||
|
10 9.1 12.5 22 28 6 | ||
|
5 4.6 6.3 41 56 5 | ||
Bessel low pass |
Nom. val. fc ‐1 dB ‐3 dB Phase del.Rise time Overshoot | ||
(Hz) (Hz) (Hz) (ms) (ms) (%) | |||
900 900 1550 0.49 0.28 4.1 | |||
400 400 750 0.8 0.6 2 | |||
200 215 395 1.3 1.0 2 | |||
100 111 190 2.5 2.1 2.5 | |||
40 39 68 5 5.5 1.1 | |||
20 21 37 8.1 10 1 | |||
10 11 19 14 19 0.7 | |||
5 5.3 9.7 25 38 0.3 | |||
2.5 2.7 4.9 48 75 0 | |||
1.25 1.4 2.4 90 150 0 | |||
0.5 0.7 1.2 180 300 0 | |||
0.2 0.17 0.3 700 1200 0 | |||
0.1 0.09 0.16 1400 2300 0 | |||
0.05 0.044 0.075 2900 4700 0 | |||
Max. permissible common‐mode voltage |
V |
±5 V | |
Common‐mode rejection |
dB |
typ. 110 | |
Max. differential voltage DC |
V |
±10 | |
Linearity deviation |
% |
typ. 0.05 | |
Long term drift over 48 hours, measuring range 2 mV/V, 30 min. after power up (warm‐up time) |
mV/V |
with autocalibration on/off <0.2 / <0.4 |