Special features

  • Up to 16 measurement inputs with TEDS sensor detection
  • 24-bit A/D converter and 19,200 Hz/38,400 Hz data rate per channel
  • Automatic synchronization of several devices
  • 32 calculation channels with peak/limit values and mathematical functions
  • Digital inputs/outputs, analog outputs
  • Fast PROFINET/EtherCAT EtherNET/IP
  • Optional: CODESYS Soft-PLC and CANopen interface
  • Robust DIN rail or wall mounting
  • Operation via web browser with three-phase user guidance (Worker, Service, Admin)

Basic device

WGX001/002

Modules

number

1 communication card, 4 measuring cards

Supply voltage range

VDC

10 to 30 (nominal (rated) voltage 24 V)

Supply voltage interruption (based on PLC standard

ms

10

DIN EN 61131−2)

24 V (− 10 %)

12 V (− 10 %)

ms

1

Power consumption at 24 V supply voltage

W

3

Basic device

per PX455

W

1.6

per PX401

W

0.75

per PX460

W

2

per PX878

W

2

EtherCATâ1) fieldbus module PX01EC

W

1.9

PROFINET fieldbus module PX01PN

W

2.3

Ethernet/IP fieldbus module PX01EP

W

2.2

Ethernet (data link) Protocol/addressing Plug connection Cable type

Max. cable length to module

m

IEEE802.3.; 10 Base-T / 100 Base-TX

TCP/IP (direct IP address or DHCP) RJ45, 8-pin

Standard LAN, CAT5, SFTP 100

Synchronization

m

Time via Ethernet

NTP protocol

HBM protocol

Plug connection Cable type Number of devices

Line lengths between neighboring devices, max.

Measured values in measuring raster and carrier frequency

(module to module)

RJ45, 8-pin Standard LAN, CAT5, SFTP

20

30

USB connection

Function

USB 2.0 Host

− Resets all device parameters to the factory settings

− Sets the device name and network settings

− Resets user passwords

− Stores measured data (using free CODESYS application)

CAN connection

CANopen interface only with WGX001 (CAN ISO11898)

Real time calculation in device Sum sampling rate Calculation channels

Update rate Function

MW/s number

Hz

CAN 2.0b

400,000

32 in real time (max. 48 for unternal calculations)

19200

Peak values, limit values, mean values, root mean square

values (RMS), tolerance bands, mathematic calculation

channels, logic functions, signal characteristics, signal

generators, 2-point scaling, 2-point controllers, PID

controllers, filters, multiplexers, sample-hold, time

calculation, counters, triggers, 3x3 matrices calculation,

SG-rosette calculation,

coordinate calculation (polar <−> cartesian), CODESYS

connection

Peak value memories

Number Reference level Function Update rate Delete

via digital inputs via fieldbus

!ls ms

ms

32

all measurement signals, all calculation channels Min./ Max., peak-to-peak

52

1

20

Limit value switches

Number

Reference level Function

Response time, typical

!ls

32, via fieldbus and Ethernet data link

8 via digital outputs per PX878 (max. 2 PX878 can be inserted)

All measurement signals, all calculation channels Overshooting/undershooting a level Within/outside a tolerance band

300