Basic device |
|
WGX001/002 |
Modules |
number |
1 communication card, 4 measuring cards |
Supply voltage range |
VDC |
10 to 30 (nominal (rated) voltage 24 V) |
Supply voltage interruption (based on PLC standard |
ms |
10 |
DIN EN 61131−2) | ||
24 V (− 10 %) | ||
12 V (− 10 %) |
ms |
1 |
Power consumption at 24 V supply voltage |
W |
3 |
Basic device | ||
per PX455 |
W |
1.6 |
per PX401 |
W |
0.75 |
per PX460 |
W |
2 |
per PX878 |
W |
2 |
EtherCATâ1) fieldbus module PX01EC |
W |
1.9 |
PROFINET fieldbus module PX01PN |
W |
2.3 |
Ethernet/IP fieldbus module PX01EP |
W |
2.2 |
Ethernet (data link) Protocol/addressing Plug connection Cable type Max. cable length to module |
m |
IEEE802.3.; 10 Base-T / 100 Base-TX TCP/IP (direct IP address or DHCP) RJ45, 8-pin Standard LAN, CAT5, SFTP 100 |
Synchronization |
−
m |
Time via Ethernet |
NTP protocol | ||
HBM protocol
Plug connection Cable type Number of devices Line lengths between neighboring devices, max. |
Measured values in measuring raster and carrier frequency (module to module) RJ45, 8-pin Standard LAN, CAT5, SFTP 20 30 | |
USB connection Function |
|
USB 2.0 Host − Resets all device parameters to the factory settings − Sets the device name and network settings − Resets user passwords − Stores measured data (using free CODESYS application) |
CAN connection |
|
CANopen interface only with WGX001 (CAN ISO11898) |
Real time calculation in device Sum sampling rate Calculation channels Update rate Function |
MW/s number
Hz |
CAN 2.0b 400,000 32 in real time (max. 48 for unternal calculations) 19200 Peak values, limit values, mean values, root mean square values (RMS), tolerance bands, mathematic calculation |
channels, logic functions, signal characteristics, signal | ||
generators, 2-point scaling, 2-point controllers, PID | ||
controllers, filters, multiplexers, sample-hold, time | ||
calculation, counters, triggers, 3x3 matrices calculation, | ||
SG-rosette calculation, | ||
coordinate calculation (polar <−> cartesian), CODESYS | ||
connection | ||
Peak value memories Number Reference level Function Update rate Delete via digital inputs via fieldbus |
!ls ms ms |
32 all measurement signals, all calculation channels Min./ Max., peak-to-peak 52
1 20 |
Limit value switches Number
Reference level Function
Response time, typical |
!ls |
32, via fieldbus and Ethernet data link 8 via digital outputs per PX878 (max. 2 PX878 can be inserted) All measurement signals, all calculation channels Overshooting/undershooting a level Within/outside a tolerance band 300 |
Modular measuring amplifier system PMX - datasheet | PDF, 0.39 Kb |