Type |
DI101 |
DI105 |
DI110 |
DI405 |
DI410 | |
Number of optical sensor chains that can be connected |
|
1 |
1 |
1 |
4 |
41) |
Wavelength range (Measuring range) |
nm |
1520 ¼ 1580 |
1510 ¼ 1590 |
1510 ¼ 1590 |
1510 ¼ 1590 |
1510 ¼ 1590 |
Wavelength variation per 10 K |
pm |
<2 | ||||
Repeatability2) |
pm |
1 resp. 0.05 with averaging of 1000 measuring values | ||||
Dynamic range |
dB |
25 (adaptable amplification) | ||||
Sampling rate |
1/s |
100 |
500 |
1000 |
500 |
1000 |
Max. data transmission rate |
1/s |
50000 | ||||
Optical connector sockets |
|
FC/APC | ||||
Ambient conditions |
°C [°F] |
0 ¼ +50 [+32 ¼ +122] | ||||
Nominal temperature range | ||||||
Ambient humidity range |
% rel. h. |
0 ¼ 80, non‐condensing | ||||
Storage temperature range |
°C [°F] |
-20 ¼ +70 [-4 ¼ +158] | ||||
Storage humidity range |
% rel. h. |
0 ¼ 95, non‐condensing | ||||
Electrical connection values Supply voltage Power pack Power consumption Interface |
V VAC W |
+12 (+7 ¼ +36) via power pack 100 ¼ 240 (with 47 ¼ 63 Hz) typ. 25, max. 50 Ethernet (TCP/IP) | ||||
Weight, approx. |
kg |
2.5 |
Interrogators for optical strain gages (SG) DI - datasheet | PDF, 0.25 Kb |