Type |
SI101 |
SI105 |
SI401 |
SI405 |
SI410 | |
Number of optical sensor chains that can be connected |
|
1 |
1 |
41) |
41) |
4 |
Wavelength range (Measuring range) |
nm |
1520 ¼ 1580 |
1510 ¼ 1590 |
1510 ¼ 1590 |
1510 ¼ 1590 |
1528 ¼ 1568 |
Absolute zero error2) |
pm |
10 | ||||
Wavelength variation per 10 K |
pm |
<2 | ||||
Repeatability3) with 1 measurement/s |
pm |
0,5 | ||||
Dynamic range |
dB |
40 |
30 |
50 |
30 |
30 |
Sampling rate |
1/s |
1 |
5 |
1 |
5 |
10 |
Optical connector sockets |
|
FC/APC | ||||
Ambient conditions |
°C [°F] |
0 ¼ +50 [+32 ¼ +122] | ||||
Nominal temperature range | ||||||
Ambient humidity range |
% rel. h. |
0 ¼ 80, non‐condensing | ||||
Storage temperature range |
°C [°F] |
-20 ¼ +70 [-4 ¼ +158] | ||||
Storage humidity range |
% rel. h. |
0 ¼ 95, non‐condensing | ||||
Electrical connection values Supply voltage Power pack Power consumption Interface |
V VAC W |
+5 via power pack 100 ¼ 240 (with 47 ¼ 63 Hz) typ. 18, max. 30 Ethernet (TCP/IP) | ||||
Weight, approx. |
kg |
2 |