General specifications | ||
Inputs |
Number |
16, electrically isolated from each other |
Transducer |
|
Thermocouples Type T (Cu −CuNi) |
Sample rates (Domaine adjustable by software, Factory setting is „HBM Classic) |
S/s |
Dezimal: 0,1 …200 (600) HBM Classic: 0,1 … 600 |
A/D converter |
|
24 Bit Delta Sigma converter |
Signal bandbwidth |
Hz |
20 (−3 dB) |
Aktive low-pass filter |
Hz |
Bessel, Butterworth 0.01 ... 20 (−3 dB), |
TEDS transducer identification max. distance between RFID transponder and housing |
mm |
RFID transponder in housing and plug 1 |
Transducer connection |
|
Mini thermocouple socket Type T |
Permissible cable length between MX1609TB and transducer |
m |
<30 |
Supply voltage range (DC) |
V |
10 ... 30, 24 V nominal (rated) voltage |
Supply voltage interruption |
|
max. 5 ms at 24 V |
Power consumption |
W |
< 6 |
Ethernet (data link) Protocol/Addressing Connection
Max. cable length to module |
− −
m |
10Base-T / 100Base-TX TCP/IP/direct IP address or DHCP 8P8C plug (RJ-45) with twisted pair cable, Streaming (CAT-5) 100 |
Synchronization options EtherCAT IRIG−B (B000 to B007; B120 to B127) IEEE 1588v2 (PTP), NTP |
|
IEEE 1394b FireWire (only QuantumX, automatically) via CX27 via MX440B- or MX840B input channel Ethernet |
FireWire (module synchronization, data link, optional supply |
MBaud |
IEEE 1394b (HBM modules only) |
voltage) |
| |
Baud rate |
400 (approx. 50 MByte/s) | |
Max. current from module to module |
A |
1.5 |
Max. cable length between the nodes |
m |
5 |
Max. number of modules connected in series (daisy |
− |
|
chain) |
|
12 (=11 Hops) |
Max. number of modules in a FireWire system (including |
|
|
hubs, backplane) |
− |
24 |
Max. number of hops |
− |
14 |
Nominal (rated) temperature range |
°C [°F] |
−20 ... +60 [−4 ... +140] |
Operating temperature range |
°C [°F] |
−20 ... +65 [−4 ... +149] |
Storage temperature range |
°C [°F] |
−40 ... +75 [−40 ... +167] |
Rel. humidity |
% |
5 ... 95 (non condensing) |
Protection class |
|
III |
Degree of protection |
|
IP20 per EN 60529 |
EMC requirements |
|
per EN 61326 |
Mechanical tests (transport tests) |
m/s2 |
50 |
Vibration (30 min) | ||
Shock (6 ms) |
m/s2 |
350 |
Maximum input voltage at transducer (to housing and ground) |
V |
60 (no transients) |
Dimensions, horizontal (H x W x D) |
mm |
52.5 x 200 x 122(with case protection) 44 x 174 x 119 (without case protection) |
Weight, approx. |
g |
900 |
QuantumX MX1609TB - datasheet | PDF, 0.26 Kb |