KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

QuantumX MX878B

Special features

  • 8 individually configurable analog outputs (electrically isolated, can be filtered)
  • Mathematics unit, peak-value unit (real-time computation)
  • Signal generator

General specifications

Supply voltage range (DC)

V

10 ... 30 (24 V nominal (rated) voltage)

Supply voltage interruption

max. für 5 ms at 24 V

Power consumption

W

7

Ethernet (data link) Protocol/addressing Connection

Max. cable length to module

m

10Base-T / 100Base-TX TCP/IP (direct IP address or DHCP)

8P8C plug (RJ-45) with twisted pair cable (CAT-5) 100

FireWire (module synchronization, data link, optional supply

MBaud

IEEE 1394b (HBM modules only)

voltage)

Baud rate

400 (approx. 50 MByte/s)

Max. current from module to module

A

1,5

Max. cable length between the nodes

m

5

Max. number of modules connected in series (daisy

12 (=11 hops)

chain)

Max. number of modules in a FireWire system (including

hubs1), backplane)

24

Max. chain of hops2)

14

Synchronisation

EtherCAT

NTP

IRIG−B (B000 to B007; B120 to B127)

FireWire (automatically, recommended) via CX27

via Ethernet

via MX440A- or MX840A input channel

Peak-value unit

Hz

4

Number of peak values

Measurment input rate, max.

4,800

Measurement output rate, max.

Hz

4,800

Signal generator

Arbitrary mode

Max. output rate

Rates that can be represented Number of buffers

Depth of buffers Waveforms

Hz

Multiple buffering, triggered continuos 96,000

Even dividers of the maximum rate 2

10,000 values in float data format Constant value, sine

Rectangle and triangle with variable duty cycle

Nominal (rated) temperature range

°C [°F]

−20 ... +60 [−4 ... +140]

Operating temperature range

°C [°F]

−20 ... +65 [−4 ... +149]

Storage temperature range

°C [°F]

−40 ... +75 [−40 ... +167]

Rel. humidity

%

5 ... 95 (non condensing)

Protection class

III

Degree of protection

IP20 per EN60529

Mechanical tests3)

m/s2

50

Vibration (30 min)

Shock (6 ms)

m/s2

350

EMC requirements

per EN 61326

Dimensions, horizontal (W x H x D)

mm

mm

52,5 x 200 x 122 (with case protection)

44 x 174 x 119 (without case protection)

Weight, approx.

880

QuantumX MX878B - datasheet PDF, 0.1 Kb