KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Junction boxes VKK1-4&VKK1R-4

Special features

  • Parallel connection of up to 4 load cells
  • Off-center load compensation via integrated resistor network
  • EMC-tested per EN 45 501 and EN 61 323 through HBM shielding design
  • Degree of protection IP65 to EN 60 529
  • VKK1R-4 with stainless housing

Type

VKK1-4

VKK1R-4

Resistor network for off-center load compensation Max. permissible voltage

V

0.39...5.71 (in 15 steps)

18

Nominal temperature range

°C [°F]

−20...+85 [−4...+185]

Operating temperature range

−20...+85 [−4...+185]

Storage temperature range

−40...+85 [−40...+185]

EMI test

V/m

10

Electromagnetic field (26...1000 MHz)

Burst (to connected cables)

V

1000

Electrostatic discharge (to housing)

V

6000

Weight, approx.

kg

1

1.5

Max. wire cross section of cable strands

mm2

1.5

Degree of protection according to EN 60529 (IEC 529)

IP65 (dust−tight and protected against water jets)

Materials Housing Sleeve nut

Clamping cone

Diecast aluminum, coated (color: RAL 7035)

PG7, SW14,

nickel−plated brass

Neoprene,

for cable−∅ 4...6.5 mm1)

Stainless steel

M12, SW14,

nickel−plated brass

Neoprene,

für cable−∅ 4...6.5 mm

Junction boxes VKK1-4&VKK1R-4 - datasheet PDF, 0.29 Kb