KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Junction boxes VKK2-8&VKK2R-8

Special features

  • Parallel connection of up to 8 load cells
  • Corner balancing via integrated resistor network
  • EMC-proof according to EN 45 501 and EN 61 323 due to HBM shielding method
  • Degree of protection IP65 to EN 60 529
  • Expandable to more than eight load cells
  • VKK2R-8 with stainless housing

Type

VKK2-8

VKK2R-8

Resistor network for corner load balancing Max. permissible voltage

V

0.22...5.93 (in 30 steps)

18

Nominal temperature range

°C

−20...+85

Operating temperature range

−20...+85

Storage temperature range

−40...+85

Interference immunity check

V/m

10

Electromagnetic field (26...1000 MHz)

Burst (to connected cables)

V

1000

Electrostatic discharge (to housing)

V

6000

Weight, approx.

kg

1

Max. wire cross section of cable strands Degree of protection

according to EN 60529

(IEC 529)

mm2

1.5

IP65 (dust−tight and protected against water jets)

Materials: Housing

Sleeve nut Clamping cone

powder−coated steel sheet Housing:

RAL 7035

stainless steel

7x M12, a.f.14, 2x M16, a.f.17

nickel−plated brass

Neoprene

Junction boxes VKK2-8&VKK2R-8 - datasheet PDF, 0.11 Kb