Type
|
Z6FD1
|
Z6FC3
|
Z6FC3MI
|
Z6FC4
|
Z6FC6
|
Accuracy class to OIML R 60
Number of scale intervals (nLC)
|
D1
1000
|
C3
3000
|
C3/MI7.5
3000
|
C4
4000
|
C6
6000
|
Nominal (rated) load (Emax)
|
kg
t
|
5; 10; 20;
50; 100;
200; 500
1
|
10; 20; 50;
100; 200;
500
1
|
50; 100;
200
-
|
20; 50; 100;
200; 500
-
|
50; 100;
200;
-
|
Minimum scale division (vmin)
Return of minimum dead load signal (DDR)
Nominal (rated) sensitivity (Cn)
Sensitivity tolerance with load appl. in spec. direction
|
% of Emax
mV/V
%
|
0.0360
-
|
0.0090
-
|
0.0066
0.5·Emax/ - -
7500
|
2
|
+(1;-0.1)
|
±0.051)
|
Temperature coefficient of sensitivity (TCS)2)
Temperature coefficient of zero signal (TK0)
|
% of Cn/10 K
|
±0.0500
±0.0500
|
±0.0080
±0.0125
|
±0.0080
±0.0093
|
±0.0070
±0.0093
|
±0.0040
±0.0093
|
Relative reversibility error (dhy)2)
Non linearity (dlin)2)
Load creep (dDR) in 30 min.
|
% of Cn
|
±0.0500
±0.0500
±0.0490
|
±0.0170
±0.0180
±0.0166
|
±0.0066
±0.0180
±0.0098
|
±0.0130
±0.0150
±0.0125
|
±0.0080
± 0.0110
±0.0083
|
Input resistance (RLC)
Output resistance (R0)
|
®
|
350...480
|
356 ±0.2
|
356 ±0.12
|
Reference voltage (Uref)
Nominal supply voltage range (Bu)
|
V
|
5
0.5...12
|
Insulation resistance (Ris)
|
G®
|
> 5
|
Nominal ambient temperature range (BT)
Operating temperature range (Btu) Storage temperature range (Btl)
|
oC
|
-10...+40
-30...+70
-50...+85
|
Limit load (EL)
Breaking load (Ed)
|
% of E
|
150
�300
|
Nominal (rated) load
|
kg
|
5
|
10
|
20
|
50
|
100
|
200
|
500
|
1000
|
Relative permissible oscillatory stress
Nominal (rated) displacement (snom) approx. Weight, (G) approx.
|
% of Emax
mm kg
|
100
0.24
0.5
|
100
0.3
0.5
|
100
0.29
0.5
|
100
0.27
0.5
|
100
0.31
0.5
|
100
0.39
0.5
|
70
0.6
0.5
|
100
0.55
2.3
|
Degree of protection (IP) as per EN60529 (IEC529)
|
|
IP 68 (tougher test conditions: 1 m water column;100 h)
|
Material: Measuring body
Bellows
Cable inlet gland Cable sheath
|
|
Stainless steel 3)
Stainless steel 3) Stainless steel / Viton® PVC
|
| | | | | | | | | | | | | |