Type
|
|
C16A D1
|
C16A C3
|
C16A C4
|
Maximum capacity (Emax)
|
|
20 t
|
30 t
|
40 t
|
60 t
|
100 t
|
20 t
|
30 t
|
40 t
|
60 t
|
100 t
|
20 t
30 t
40 t
|
60 t
|
Accuracy class according to OIML R60
|
|
D1 (0.0330 %)
|
C3 (0.0170 %)
|
C4
|
Number of load cell verification intervals (nLC)
|
|
1000
(10000 NTEP III LM)
|
3000
|
4000
|
Minimum load cell verification inter val (vmin)
|
% of Emax
|
0.0200
(0.0068 NTEP III LM)
|
0.0100
|
0.0083
|
0.0167
|
0.0100
|
0.0083
|
[Option: 0.0050]
|
|
Nominal (rated) sensitivity (Cn)
|
mV/V
|
2
|
Sensitivity tolerance 1)
|
%
|
±0.5 1)
|
Temperature coefficient of sensitiv ity (TCS) 2)
|
% of Cn/1
0 K
|
2)
|
2)
|
2)
|
Temperature coefficient of zero sig nal (TC0)
|
±0.0285
|
±0.0140
|
±0.0116
|
±0.0234
|
±0.0140
|
±0.0116
|
Relative reversibility error (dhy) 2)
|
% of Cn
|
±0.0330 2)
|
±0.0170 2)
|
±0.0140
|
Non-linearity (dlin) 2)
|
±0.0300 2)
|
±0.0180 2)
|
±0.0120
|
Creep upon loading (dcr) over 30 min.
|
±0.0330
|
±0.0167
|
±0.0125
|
Minimum dead load output return (DR), 30 min.
|
±0.0330 (±0.0150 NTEP III LM)
|
±0.0167
|
±0.0125
|
Repeatability error (max. change in load cell output for repeated loading)
|
±0.005
|
Input resistance (RLC) (black-blue)
|
Ω
|
700 ±20
|
Output resistance (R0) 1) (red-white)
|
706 ±3.5 1)
|
Reference excitation voltage (Uref)
|
V
|
5
|
Nominal (rated) range of the excitation voltage (BU)
|
0.5 ... 12
|
Insulation resistance (Ris)
|
GΩ
|
> 5
|
Nominal (rated) range
of the ambient temperature (BT)
|
°C
|
-10 ... +40
|
Operating temperature range (Btu)
|
-50 ... +70
|
Storage temperature range (Btl)
|
-50 ... +85
|
Limit load (EL)
|
% of Emax
|
150
|
Breaking load (Ed)
|
> 350
|
Relative permissible oscillatory stress (Fsrel)
(oscillation bandwidth as per DIN
50100 with 10,000,000 load changes)
|
70
|
|
|
|
Maximum capacity (Emax)
|
|
20 t
|
30 t
|
40 t
|
60 t
|
100 t
|
Deflection at Emax (snom), approx.
|
mm
|
0.65
|
0.75
|
0.85
|
1.22
|
1.57
|
Weight (G) with cable, approx.
|
kg
|
2.1
|
2.3
|
2.9
|
3.7
|
8
|
Degree of protection per EN60529 (IEC529)
|
|
IP68 (test conditions 1 m water column/100 h) IP69 K (water at high pressure, steam jet cleaning)
|
Material: Measuring body + housing Cable entry
Seal
Cable sheath
|
|
stainless steel 3)
stainless steel4) (Emax 100 t: nickel-plated brass)
Viton® (Emax 100 t: silicone) thermoplastic elastomer
|
| | | | | | | | | | | | | | | | |