Products

Canister Load Cell C2

Special features

  • Load cells made of stainless materials
  • Max. capacities: 50 kg ... 50 t
  • Small deflection
  • High permissible dynamic load
  • Six-wire circuit
  • Low profile
  • Meets EMC requirements according to EN 45 501
  • Explosion proof version acc. to ATEX 95 (optional)

Type

Accuracy class Max. capacity

kg t

C2

0.2

50

0.1

100, 200, 500

1, 2, 5, 10, 20, 50

Sensitivity (Cn)

mV/V

2

Tolerance on sensitivity

%

< +0.20

Temperature effect on sensitivity (TKC)

in the nominal temperature range

in the service temperature range

%/10 K

%/10 K

< +0.05

< +0.10

Temperature effect on zero balance (TK0)

in the nominal temperature range

in the service temperature range

%/10 K

%/10 K

< +0.05

<+ 0.10

Hysteresis error (dhy)

Non-linearity (dlin) Creep (dDR) over 30 min.

%

%

%

< +0.15

< +0.20 < +0.10

< +0.06

Input resistance (RLC)

Output resistance (R0)

340 ...450

356 + 0.2

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

Max. permissible excitation voltage

V

V

0.5...10

12

0.5...12

18

Insulation resistance (Ris)

Nominal temoerarure range (BT) Operating temperature range (Btu) Storage temperature range (Btl)

GΩ

oC [oF]

oC [oF]

oC [oF]

>5

- 10...+ 40 [14...104]

- 30...+ 85 [-22...185] ( - 30...+ 120 ) 1) [-22...248]1

- 50...+ 85 [-58...185]

Safe load limit (EL)

Breaking load (Ed

Rel. static lateral load limit (Elq) Permissible dynamic load (Fsrel)

(peak to peak acc. to DIN 50100)

% of rated capacity

130

150

300

50

100

Degree of protection class (IP) to EN 60 529 (IEC 529)

Material: Measuring body

Cable gland Cable sheath

IP 68 (test conditions: 100 h at 1 m water column) IP 69 K (water at high pressure, steam jet cleaning)

Stainless steel

Nickel plated brass, Silicone Thermoplastic elastomer

Canister Load Cell C2 - datasheet PDF, 0.36 Kb