Type
Max. capacity (Emax)
|
C2A/..., C2A/.../EExd
1t / 2t / 5t / 10t
|
Accuracy class to OIML R60
Max. number of load cell intervalls (nLC) Min. load cell verification interval (vmin)
|
% of Emax
|
D1
1000
0.0286
|
C3
3000
0.0100
|
Sensitivity (Cn)
Tolerance on sensitivity
|
mV/V
%
|
2
|
± 0.1000
|
± 0.0500
|
Temperature effect on sensitivity (TKC)1)
Temperature effect on zero signal (TK0)
|
% of Cn / 10 K
|
± 0.0500
± 0.0400
|
± 0.0080
± 0.0140
|
Hysteresis1)
)1)
Creep (dDR) in 30 min
|
% of Cn
|
± 0.0500
± 0.0500
± 0.0500
|
± 0.0180
± 0.0170
± 0.0167
|
Input resistance (RLC) (black-blue)
Output resistance (R0) (red-white)
|
Ω
|
400 ... 430
|
356 ±1.5
|
356 ±0.12
|
Reference excitation volt. (Uref)
Nominal range of excitation voltage (BU)
|
V
|
5
0.5 ... 12
|
Isolation Resistance (Ris)
|
GΩ
|
>5
|
Nominal temperature range (BT)2)
Service temperature range (Btu) Storage temperature range (Btl)
|
oC [oF]
|
− 10 ... +40 [+14 ... +104]
− 30 ... +70 [−22 ... +158]
− 50 ... +85 [−58 ... 185]
|
Save load limit (EL)
Breaking load (Ed) Side load limit (Elq)
Permissible dynamic load (Fsrel)3)
(Vibration amplitude to DIN 50100)
|
% of Emax
|
150
300
50
100
|
Deflection at max. capacity, (snom) (± 15%)
Weight (G), approx.
|
mm
kg
|
0.15 / 0.15 / 0.17 / 0.2
1.7 / 1.8 / 1.8 / 1.8
|
Protection class (IP) to EN 60529 (IEC529)
|
|
IP 67 / IP68 (more rigorous test conditions: 1mWs, 100h)
|
Material, Measuring body
Cable gland Cable sheath
|
|
stainless steel
nickel plated brass 4), silicone thermoplast. elastomer
|