KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Canister Load Cell Z16A

Special features

  • Nominal (rated) loads: 7.5 t, 15 t
  • Simple installation
  • Rust-resistant materials, laser-welded, IP68, IP69K
  • Accuracy class up to C3 (OIML R60 test report)
  • Optimized for parallel connection by off-center load compensation
  • Meets EMC requirements as per EN 45501
  • Adapter for M36x3 internal thread available
  • Six-wire configuration

Type

Z16AD1

Z16AC3

Accuracy class 

D1

C3

Number of load cell verification intervals

nLC

1000

3000

Nominal (rated) load

Emax

t

7.5

15

15

Minimum load cell verification interval

vmin

Emax/5000

Emax/10,000

Temperature coefficient of zero signal per 10K

TC0

% of Cn

±0.0285

±0.0140

Nominal (rated) sensitivity 

Cn

mV/V

2

Sensitivity tolerance

%

±0.5

Temperature coefficient of sensitivity per 10K 

TCS

% of Cn

±0.0250

±0.0080

Linearity error 

dlin

±0.0300

±0.0180

Relative reversibility error 

dhy

±0.0330

±0.0170

Load creep in 30 min.

dcr

±0.0330

±0.0167

Input resistance

RLC

Ω

700 ±20

Output resistance 

R0

706 ±3.5

Reference excitation voltage

Uref

V

5

Nominal (rated) range of the excitation voltage

BU

0.5 ... 12

Insulation resistance at 100VDC

Ris

> 5

Nominal (rated) ambient temperature range

BT

°C

−10 ... +40

Operating temperature range

Btu

−30 ... +70

Storage temperature range

Btl

−50 ... +85

Limit load

EL

% of Emax

150

Breaking load

Ed

> 350

Relative permissible oscillatory stress (oscillation width as per DIN 50100)

Fsrel

70

Nominal (rated) displacement at Emax, approx.

snom

mm

0.20

0.27

0.27

Weight without cable, approx.

G

kg

2.3

Degree of protection per DIN EN 60529 (IEC 529)

IP68 (test conditions: 100 hours under 1m water column); IP69 K (water at high pressure, steam cleaner) 

Cable length, six-wire configuration

12 m

Material: Measuring body+housing Cable entry

Seal

Cable sheath

Stainless steel 

Stainless steel

V ®

iton

Thermoplastic elastomer

Type

Z16AD1

Z16AC3

Accuracy class 

D1

C3

Number of load cell verification intervals

nLC

1000

3000

Nominal (rated) load

Emax

t

7.5

15

15

Minimum load cell verification interval

vmin

Emax/5000

Emax/10,000

Temperature coefficient of zero signal per 10K

TC0

% of Cn

±0.0285

±0.0140

Nominal (rated) sensitivity 

Cn

mV/V

2

Sensitivity tolerance

%

±0.5

Temperature coefficient of sensitivity per 10K 

TCS

% of Cn

±0.0250

±0.0080

Linearity error 

dlin

±0.0300

±0.0180

Relative reversibility error 

dhy

±0.0330

±0.0170

Load creep in 30 min.

dcr

±0.0330

±0.0167

Input resistance

RLC

Ω

700 ±20

Output resistance 

R0

706 ±3.5

Reference excitation voltage

Uref

V

5

Nominal (rated) range of the excitation voltage

BU

0.5 ... 12

Insulation resistance at 100VDC

Ris

> 5

Nominal (rated) ambient temperature range

BT

°C

−10 ... +40

Operating temperature range

Btu

−30 ... +70

Storage temperature range

Btl

−50 ... +85

Limit load

EL

% of Emax

150

Breaking load

Ed

> 350

Relative permissible oscillatory stress (oscillation width as per DIN 50100)

Fsrel

70

Nominal (rated) displacement at Emax, approx.

snom

mm

0.20

0.27

0.27

Weight without cable, approx.

G

kg

2.3

Degree of protection per DIN EN 60529 (IEC 529)

IP68 (test conditions: 100 hours under 1m water column); IP69 K (water at high pressure, steam cleaner) 

Cable length, six-wire configuration

12 m

Material: Measuring body+housing Cable entry

Seal

Cable sheath

Stainless steel 

Stainless steel

V ®

iton

Thermoplastic elastomer

Canister Load Cell Z16A - datasheet PDF, 0.06 Kb