Type |
Z16AD1 |
Z16AC3 | |||
Accuracy class |
D1 |
C3 | |||
Number of load cell verification intervals |
nLC |
|
1000 |
3000 | |
Nominal (rated) load |
Emax |
t |
7.5 |
15 |
15 |
Minimum load cell verification interval |
vmin |
|
Emax/5000 |
Emax/10,000 | |
Temperature coefficient of zero signal per 10K |
TC0 |
% of Cn |
±0.0285 |
±0.0140 | |
Nominal (rated) sensitivity |
Cn |
mV/V |
2 | ||
Sensitivity tolerance |
|
% |
±0.5 | ||
Temperature coefficient of sensitivity per 10K |
TCS |
% of Cn |
±0.0250 |
±0.0080 | |
Linearity error |
dlin |
±0.0300 |
±0.0180 | ||
Relative reversibility error |
dhy |
±0.0330 |
±0.0170 | ||
Load creep in 30 min. |
dcr |
±0.0330 |
±0.0167 | ||
Input resistance |
RLC |
Ω |
700 ±20 | ||
Output resistance |
R0 |
706 ±3.5 | |||
Reference excitation voltage |
Uref |
V |
5 | ||
Nominal (rated) range of the excitation voltage |
BU |
0.5 ... 12 | |||
Insulation resistance at 100VDC |
Ris |
GΩ |
> 5 | ||
Nominal (rated) ambient temperature range |
BT |
°C |
−10 ... +40 | ||
Operating temperature range |
Btu |
−30 ... +70 | |||
Storage temperature range |
Btl |
−50 ... +85 | |||
Limit load |
EL |
% of Emax |
150 | ||
Breaking load |
Ed |
> 350 | |||
Relative permissible oscillatory stress (oscillation width as per DIN 50100) |
Fsrel |
70 | |||
Nominal (rated) displacement at Emax, approx. |
snom |
mm |
0.20 |
0.27 |
0.27 |
Weight without cable, approx. |
G |
kg |
2.3 | ||
Degree of protection per DIN EN 60529 (IEC 529) |
IP68 (test conditions: 100 hours under 1m water column); IP69 K (water at high pressure, steam cleaner) | ||||
Cable length, six-wire configuration |
12 m | ||||
Material: Measuring body+housing Cable entry Seal Cable sheath |
Stainless steel Stainless steel V ® iton Thermoplastic elastomer | ||||
Type |
Z16AD1 |
Z16AC3 | |||
Accuracy class |
D1 |
C3 | |||
Number of load cell verification intervals |
nLC |
|
1000 |
3000 | |
Nominal (rated) load |
Emax |
t |
7.5 |
15 |
15 |
Minimum load cell verification interval |
vmin |
|
Emax/5000 |
Emax/10,000 | |
Temperature coefficient of zero signal per 10K |
TC0 |
% of Cn |
±0.0285 |
±0.0140 | |
Nominal (rated) sensitivity |
Cn |
mV/V |
2 | ||
Sensitivity tolerance |
|
% |
±0.5 | ||
Temperature coefficient of sensitivity per 10K |
TCS |
% of Cn |
±0.0250 |
±0.0080 | |
Linearity error |
dlin |
±0.0300 |
±0.0180 | ||
Relative reversibility error |
dhy |
±0.0330 |
±0.0170 | ||
Load creep in 30 min. |
dcr |
±0.0330 |
±0.0167 | ||
Input resistance |
RLC |
Ω |
700 ±20 | ||
Output resistance |
R0 |
706 ±3.5 | |||
Reference excitation voltage |
Uref |
V |
5 | ||
Nominal (rated) range of the excitation voltage |
BU |
0.5 ... 12 | |||
Insulation resistance at 100VDC |
Ris |
GΩ |
> 5 | ||
Nominal (rated) ambient temperature range |
BT |
°C |
−10 ... +40 | ||
Operating temperature range |
Btu |
−30 ... +70 | |||
Storage temperature range |
Btl |
−50 ... +85 | |||
Limit load |
EL |
% of Emax |
150 | ||
Breaking load |
Ed |
> 350 | |||
Relative permissible oscillatory stress (oscillation width as per DIN 50100) |
Fsrel |
70 | |||
Nominal (rated) displacement at Emax, approx. |
snom |
mm |
0.20 |
0.27 |
0.27 |
Weight without cable, approx. |
G |
kg |
2.3 | ||
Degree of protection per DIN EN 60529 (IEC 529) |
IP68 (test conditions: 100 hours under 1m water column); IP69 K (water at high pressure, steam cleaner) | ||||
Cable length, six-wire configuration |
12 m | ||||
Material: Measuring body+housing Cable entry Seal Cable sheath |
Stainless steel Stainless steel V ® iton Thermoplastic elastomer |
Canister Load Cell Z16A - datasheet | PDF, 0.06 Kb |