KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Single Point Load Cell FIT®/0

Special features

  • 4 limit switches with hysteresis
  • Dosing functionalities and diagnostic channel (Type E)
  • High overload limits
  • Degree of protection IP67
  • Fast triggering and scaling of the measured value
  • Trigger function (external or level trigger)
  • Test report for 3000 d accord. to OIML R 60, R 76

Type

FIT/0...

Accuracy class according to OIML R60

C3

Max. capacity (Emax)

Min. load cell verification interval (vmin)

Min. application range for 3000 d

kg

g kg

5

0.5

1.5

10

1

3

20

2

6

50

5

15

75

10

30

Max. platform size

mm

L 400 x W 400

L 600 x W 500

Max. number of load cell verification intervals (nLC) Apportionment factor (pLC)

3000

1

Temperature effect on sensitivity (TKC)1) 2)

in temperature range 0 5C...+40 5C [32 5F...+104 5F]

Temperature effect on zero signal (TKS0)2)

% of Cn/10K

±0.0250

±0.0200

Hysteresis factor (dhy)1) 2)

Nonlinearity (dlin)1) 2)

Creep (dCR) over 30 min

Eccentric loading error acc. to OIML R76

% of C

±0.0166

±0.0166

±0.0166

±0.0233

Service load (EU); max. 120 mm eccentricity Safe load limit (EL); max. 20 mm eccentricity Permissible dyn. load (Fsrel)

max. 50 mm eccentricity

% of Emax

150

300 (without overload protection)

70

Deflection at max. capacity (snom)

mm

< 0.15

Power supply:

Supply voltage UB1 (DC) Power consumption Switch-on current

V W A

+ 10 ... +30

� 2

0.2

Resolution of meas. signal (1 Hz-Filter)

Measuring rate

Adjustable cut-off frequency of the digital filters: Filtermode 0

Filtermode 1 (response time 62 ... 365 ms) Baud rate (RS-232-, RS-485-interface)

Max. number of bus members

Bit

1/s

Hz Hz Baud

20

4 ... 1200

200 ... 0.25

18 ... 2.5

1200; 2400; 4800; 9600; 19200; 38400; 57600;

115200

90

CANOpen interface

Baud rate

Baud

Standard CiA DS301

10 000 ... 1 000 000

DeviceNet interface

Baud rate

Baud

Release 2.0 ODVA

125 000 ... 500 000

max. cable length (CANOpen, DeviceNet)

m

::; 5000 (10KBaud)... ::; 100 (500KBaud),

::; 25 (1MBaud)

Diagnostic channel, RS-485-2-wire (extended version E, plug 2)

Baud rate

max. cable length

Max. number of bus members

Baud m

38 400

500

90

Asynchronous serial interface (plug 1)

RS-485, 4 wire, max. cable length RS-232 max. cable length

m m

500

15

Trigger input (plug 1)

Permissible input voltage Low-level

High-level

Input resistance

V V V

kΩ

0 ... +12

< 1

> 4

10

Control inputs (extended version E, plug 2)

Permissible input voltage Low-level

High-level

Input resistance

V V V

kΩ

isolated, reference potential GND2

0 ... +30

< 6

>10

> 3

Control outputs (extended version E, plug 2)

External supply voltage UB2 Max. current of one output

Accumulated current of all outputs Voltage drop

V A A V

isolated, reference potential GND2

+11 ... +30

< 0.5

< 1.0

< 1

Single Point Load Cell FIT®/0 - datasheet PDF, 0.11 Kb