Special features

  • OIML-R60 approval
  • Max. capacities: 50 kg ... 300 kg
  • Off center load compensated (OIML R76)
  • Meets EMC standards (EN 45 501)
  • Shielded connection cable
  • 6-wire circuit
  • Optional:

  • Reduced minimum LC verification interval (vmin) for multi range applications
  • Explosion proof versions
  • different cable lengths
  • Aligned output, suitable for con- nection in parallel

Type

PW10A...

Accuracy class1)

Number of load cell intervals (nLC)

C3, C3MR

3000

Maximum capacity (Emax)

kg

50

100

150

200

250

300

Minimum LC verification interval (vmin), (Accuracy class C3)

g

10

20

20

50

50

50

Temperature effect on zero balance (TK0), (Accuracy class C3)

% of Cn / 10 K

±0.0280

±0.0280

±0.0186

±0.0350

±0.0280

±0.0233

Minimum LC verification interval (vmin), (Accuracy class C3MR)

g

5

10

10

20

20

20

Temperature effect on zero balance (TK0), (Accuracy class C3MR)

% of Cn / 10 K

±0.0140

±0.0140

±0.0093

±0.0140

±0.0112

±0.0093

Max. platform size

mm

600 x 500

Sensitivity (Cn)2)

mV/V

2.0 ±0.2 (Option 6: A = 2 mV/V ±0.1 %)

Zero balance

0 ±0.1

Temperature effect on sensitivity (TKC)3)

Temperature range:

+20 ... +40 °C [+70 ... +105 °F]

−10 ... +20 °C [+15 ... +70 °F]

% of Cn

/ 10 K

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

300 ... 500

Output resistance (R0)

330 ... 430 (Option 6: A = 410 Ω ±0.2 Ω)

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

0 ... 12

Max. excitation voltage

15

Insulation resistance (Ris) at 100 VDC

GΩ

> 2

Nominal temperature range (BT)

°C [°F]

−10 ... +40 [+14 ... +104]

Service temperature range (Btu)

−10 ... +50 [+14 ... +122]

Storage temperature range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL)

at max. eccentricity

% of Emax

mm

150

150

Lateral load limit (Elq), static

%

of Emax

300

Breaking load (Ed)

300

Deflection at Emax (snom), approx.

<0,5

Weight (G), approx.

0,6

Protection class accord. to EN 60 529 (IEC 529)

IP67

Material: Measuring element Coating

Cable sheath

Aluminum Silicone rubber PVC

Single Point Load Cell PW10A - datasheet PDF, 0.16 Kb