KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Single Point Load Cell PW12C

Special features

  • OIML-R60 approval
  • Max. Capacities: 50 kg...750 kg
  • Off center load compensated (OIML R76)
  • Meets EMC standards (EN 45 501)
  • 6-wire circuit
  • Optional:

  • Reduced minimum LC verification interval (vmin) for multi range applications
  • Explosion-proof versions
  • Different cable lengths
  • Aligned output, suitable for con- nection in parallel

Type

PW12C...

Accuracy class1)

Number of load cell intervals (nLC)

C3; C3MR

3000

Maximum capacity (Emax)2)

kg

50

75

100

150

200

250

300

500

635

750

Minimum LC verification interval (vmin) Accuracy class C3

g

10

10

20

20

50

50

50

100

100

100

Temperature effect on zero balance (TK0) Accuracy class C3

% v. Cn / 10 K

±0.0280

±0.0186

±0.0280

±0.0186

±0.0350

±0.0280

±0.0233

±0.0280

±0.0221

±0.0186

Minimum LC verification interval (vmin) Accuracy class C3MR

g

5

5

10

10

20

20

20

50

50

50

Temperature effect on zero balance (TK0) Accuracy class C3MR

% v. Cn / 10 K

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

±0.0112

±0.0093

±0.0140

±0.0110

±0.0093

Max. platform size

mm

800 x 800

Sensitivity (Cn)

mV/V

2.0 ±0.2 (Option 6: A = 2mV/V±0.1%)

Zero balance

0 ±0.1

Temperature effect on sensitivity (TKC)3)

Temperature range

+20 ... +40 5C [+68 ... +104 5F]

−10 ... +20 5C [+14 ... +68 5F]

% of Cn

/ 10 K

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

300 ... 500

Output resistance (R0)

330 ... 430 (Option 6: A = 410 Ω ±0.2 Ω)

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

15

Max. excitation voltage

15

Insulation resistance (Ris) at 100 VDC

GΩ

> 2

Nominal temp. range (BT)

°C [°F]

−10 ... +40 [+14 ... +104]

Service temp. range (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL), at max. 100mm eccentricity

% of Emax

150

Lateral load limit (Elq), static

% of Emax

300

Breaking load (Ed)

300

Deflection at Emax (snom), approx.

mm

< 0.5

Weight (G), approx.

kg

2.4

Protection class according to EN 60 529 (IEC 529)

IP67

Material: Measuring element Coating

Cable sheath

Aluminum Silicone rubber PVC

Single Point Load Cell PW12C - datasheet PDF, 0.24 Kb