Type |
PW22... | ||||
Accuracy class1) Maximum number of load cell intervals (nLC) |
C3MR 3000 | ||||
Maximum capacity (Emax) |
kg |
6 |
10 |
20 |
30 |
Minimum LC verification interval (vmin) |
g |
0.5 |
1 |
2 |
2 |
Max. platform size |
mm |
400 x 400 | |||
Sensitivity (Cn) |
mV/V |
1.9 ±0.1 | |||
Zero signal (without pre load) |
mV/V |
0 ±0.1 | |||
Temperature effect on zero balance (TK0) |
% of Cn/ 10 K |
±0.0117 |
±0.0140 |
±0.0140 |
±0.0093 |
Temperature effect on sensitivity (TKC) 2) in the temperature range +20 ... +40 5C −10 ... +20 5C |
% of Cn / 10 K |
±0.0175
±0.0117 | |||
Relative reversibility error (dhy) 2) |
% of Cn |
±0.0166 | |||
Linearity deviation (dlin) 2) |
±0.0166 | ||||
Ratio of minimum dead load output re- turn (DR) |
±0.0166 | ||||
Off−center load error 3) |
±0.0233 | ||||
Input resistance (RLC) |
Ω |
300...500 | |||
Output resistance (R0) |
300...500 | ||||
Reference excitation voltage (Uref) |
V |
5 | |||
Nominal range of excitation voltage |
V |
1...12 | |||
Max. excitation voltage (BU) |
V |
15 | |||
Isolation resistance (Ris) at 100 VDC |
GΩ |
> 1 | |||
Nominal (rated) range of ambient tempe- rature (BT) |
°C [°F] |
−10 ... +40 [14 ... 104] | |||
Operating temperature range (Btu) |
−20 ... +50 [−4 ... 122] | ||||
Storage temperature range (Btl) |
−25 ... +70 [−13 ... 158] | ||||
Limit load (EL) at 120 mm eccentricity |
% of Emax |
150 | |||
Lateral load limit (Elq), static |
> 300 | ||||
Permissible dyn. load (Fsrel); with max. 50 mm eccentricity |
70 | ||||
Breaking load (Ed) at 20 mm eccentricity |
500 | ||||
Nominal (rated) displacement at Emax (snom), approx. |
mm |
< 0.15 | |||
Resonance frequency, without load, approx. |
Hz |
280 |
380 |
540 |
660 |
Weight (G), approx. |
kg |
0.5 | |||
Degree of protection acc. to EN 60 529 (IEC 529) |
|
IP67 | |||
Material: Measuring body Application protection Cable sheath |
|
Aluminum Silicone rubber PVC |