Type |
PW27/... | ||
Accuracy class 1) Max. number of scale intervals (nLC) |
C3MR 3000 | ||
Nominal load (Emax) |
kg |
10 |
20 |
Minimum scale division (vmin) |
g |
1 |
2 |
Max. platform size |
mm |
400 x 400 | |
Nominal (rated) sensitivity (Cn) |
mV/V |
2.0 ±0.2 | |
Zero signal (without initial load) |
mV/V |
0 ±0.1 | |
Temperature coefficient of sensitivity (TKC)2) In the range +20 ... +40°C [+68 ... +104°F] In the range -10 ... +20°C [+14 ... +68°F] |
% of Cn / 10K |
±0.0175 ±0.0117 | |
Temperature coefficient of zero signal (TK0) |
±0.0140 | ||
Relative reversibility error (dhy) 2) |
% of Cn |
±0.0166 | |
Non‐linearity (dlin)2)) |
±0.0166 | ||
Return of initial load signal (DR) |
±0.0166 | ||
Off‐center load error3) |
±0.0233 | ||
Input resistance (RLC) |
Ω |
380 ±15 | |
Output resistance (RLC) |
360 ±10 | ||
Reference excitation voltage (Uref) |
V |
5 | |
Nominal excitation voltage range (BU) |
1 ... 12 | ||
Max. excitation voltage |
15 | ||
Insulation resistance (Ris) at 100 VDC |
GΩ |
> 1 | |
Nominal ambient temperature range (BT) |
°C [°F] |
-10 ... +40 [+14 ... +104°F] | |
Operating temperature range (BT) |
-20 ... +70 [-4 ... +160°F] | ||
Storage temperature range (BT) |
-25 ... +90 [-13 ... +195°F] | ||
Operational load (EU) at max. 120 mm eccentricity |
% of Emax |
150 | |
Limit load (EL) at 20 mm eccentricity |
1000 | ||
Limit lateral loading (Elq), static |
200 | ||
Breaking load (Ed) |
> 1500 | ||
Relative perm. vibrational stress (Fsrel) at max. 50 mm eccentricity |
70 | ||
Nominal (rated) displacement at Emax (snom), approx. |
mm |
< 0.18 | |
Resonance frequency, approx. |
Hz |
330 | |
Weight (G), approx. |
kg |
0.8 | |
Degree of protection per EN 60 529 (IEC 529) |
|
IP68 (test conditions 1 m water column / 100 hours); IP69K (water at high pressure, steam cleaner) 4) | |
Material: Measuring body Seal Cable sheath |
|
Stainless steel 5) NBR PUR |
Single Point Load Cell PW27 - datasheet | PDF, 0.08 Kb |