KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Single Point Load Cell PW2C

Special features

  • Accuracy classes C3/C3MR and C6/C6MR with OIML-R60 test report
  • Max. capacities: 7.2 kg ... 72 kg
  • Off center load compensated (OIML R 76)
  • Degree of protection IP67 (according to EN 60 529)
  • Shielded connection cable
  • Optimized for static weighing applications
  • Optional:

  • Different accuracy classes with OIML-R60 test report
  • Connection cable in six wire circuit
  • Different cable lengths
  • Aligned output, suitable for connection in parallel

Type

PW2C...

Accuracy class1)

Maximum number of load cell intervals (nLC)

C3, C3MR

3000

Maximum capacity (Emax)2)

kg

7.2

12

18

36

72

Minimum LC verification interval (vmin) (Accuracy class C3)

g

1

2

5

10

20

Temperature effect on zero balance (TK0) (Accuracy class C3)

% of Cn

/ 10 K

±0.0194

±0.0233

±0.0389

±0.0389

±0.0389

Minimum LC verification interval (vmin) (Accuracy class C3MR)

g

0.5

1

2

5

10

Temperature effect on zero

balance (TK0) (Accuracy class C3MR)

% of Cn

/ 10 K

±0.0097

±0.0116

±0.0155

±0.0194

±0.0194

Max. platform size

mm

380 x 380

Sensitivity (Cn)

mV/V

2.2 ±0.2

Zero signal

mV/V

0 ±0.12

Temperature effect on sensitivity (TKC) 3) in the temperature range

+20 ... +40 °C [+68 ... +104 °F]

−10 ... +20 °C [+14 ... +68 °F]

% of Cn

/ 10 K

±0.0175

±0.0117

Relative reversibility error (dhy) 3) Linearity deviation (dlin) 3) Minimum dead load output return

(MDLOR)

Off-center load error 4)

% of Cn

±0.0166

±0.0166

±0.0166

±0.0233

Input resistance (RLC)

Output resistance (R0)

300...500

300...500

Reference excitation voltage (Uref) Nom. range of excitation voltage (BU)

V

5

1 ... 12

Isolation resistance (Ris) at 100 VDC

GΩ

> 2

Nominal (rated) range of ambient temperature (BT)

°C [°F]

−10 ... +40 [+14 ... +104]

Operating temperature range (Btu)

−10 ... +50 [+14 ... +122]

Storage temperature range (Btl)

−25 ... +70 [−13 ... +158]

Limit load (EL) *)

*) at max. eccentricity

%

of Emax

150

mm

160

Lateral load limit (Elq), static

Breaking load (Ed)

%

of Emax

300

300

Nominal (rated) displacement at Emax (snom), approx.

mm

< 0.5

Weight (G), approx.

kg

0.25

Degree of protection acc. to EN 60 529 (IEC 529)

IP67

Material: Measuring body

Application protection Cable sheath

Aluminum Silicone rubber PVC

Single Point Load Cell PW2C - datasheet PDF, 0.17 Kb