Type |
PW6C... | |||||||
Accuracy class 1) Maximum number of load cell intervals (nLC) |
C3, C3MR | |||||||
3000 | ||||||||
Maximum capacity (Emax) |
kg |
3 |
5 |
10 |
15 |
20 |
30 |
40 |
Minimum LC verification interval (vmin), (Accuracy class C3) |
g |
0.5 |
1 |
2 |
2 |
5 |
5 |
10 |
Temperature effect on zero balance (TK0) (Accuracy class C3) |
% of Cn / 10K |
0.0233 |
0.0280 |
0.0280 |
0.0186 |
0.0350 |
0.0233 |
0.0350 |
Minimum LC verification interval (vmin), (Accuracy class C3MR) |
g |
0.2 |
0.5 |
1 |
1 |
2 |
2 |
5 |
Minimum LC verification interval (vmin) (Accuracy class C3MR) |
% of Cn / 10K |
0.0093 |
0.0140 |
0.0140 |
0.0093 |
0.0140 |
0.0093 |
0.0175 |
Max. platform size |
mm |
300 x 300 | ||||||
Sensitivity (Cn) |
mV/V mV/V |
2.2 0.2 | ||||||
Zero signal |
0 0.12 | |||||||
Temperature effect on sensitivity (TKC) 2) in the temperature range +20 ... +40 °C [+68 ... +104 °F] - 10 ... +20 °C [+14 ... +68 °F] |
% of Cn / 10K |
0.0175 0.0117 | ||||||
Relative reversibility error (dhy) 2) |
% of Cn % of Cn
% of Cn
% of Cn |
0.0166 | ||||||
Non-linearity (dlin) 2) |
0.0166 | |||||||
Ratio of minimum dead load output return (DR) |
0.0245 | |||||||
Off-center load error 3) |
0.0233 | |||||||
Input resistance (RLC) |
Ω Ω |
300...500 | ||||||
Output resistance (R0) |
300...500 | |||||||
Reference excitation voltage (Uref) |
V V |
5 | ||||||
Nom. range of excitation voltage (BU) |
1 ... 12 | |||||||
Isolation resistance (Ris) at 100 VDC |
GΩ |
> 2 | ||||||
Nominal (rated) range of ambient temperature (BT) |
°C [°F] °C [°F] °C [°F] |
- 10 ... +40 [+14 ... +104] | ||||||
Operating temperature range (Btu) |
- 10 ... +50 [+14 ... +122] | |||||||
Storage temperature range (Btl) |
- 25 ... +70 [- 13 ... +158] | |||||||
Limit load (EL) *)
*) at max. eccentricity |
% of Emax mm % |
150
100 | ||||||
Lateral load limit (Elq), static |
of E% of E |
300 | ||||||
Breaking load (Ed) |
300 | |||||||
Nominal (rated) displacement at Emax (snom), approx. |
mm |
< 0.5 | ||||||
Weight (G), approx. |
kg |
0.25 | ||||||
Degree of protection acc. to EN 60 529 (IEC 529) |
|
IP67 | ||||||
Material: Measuring body Application protection Cable sheath |
|
Aluminum Silicone rubber PVC |
Single Point Load Cell PW6C - datasheet | PDF, 0.16 Kb |