KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Single Point Load Cell PW6C

Special features

  • Accuracy class C3 with OIML-R60 test report
  • Off center load compensated (OIML R 76)
  • Max. capacities: 3 kg ... 40 kg
  • Degree of protection IP67 (according to EN 60 529)
  • Shielded connection cable
  • Optimized for static weighing applications
  • Optional:

  • Accuracy class C6 with OIML-R60 test report
  • Connection cable in six wire circuit
  • Different cable lengths
  • Aligned output, suitable for connection in parallel

Type

PW6C...

Accuracy class 1)

Maximum number of load cell intervals (nLC)

C3, C3MR

3000

Maximum capacity (Emax)

kg

3

5

10

15

20

30

40

Minimum LC verification interval (vmin), (Accuracy class C3)

g

0.5

1

2

2

5

5

10

Temperature effect on zero balance (TK0) (Accuracy class C3)

% of Cn

/ 10K

0.0233

0.0280

0.0280

0.0186

0.0350

0.0233

0.0350

Minimum LC verification interval (vmin), (Accuracy class C3MR)

g

0.2

0.5

1

1

2

2

5

Minimum LC verification interval (vmin) (Accuracy class C3MR)

% of Cn

/ 10K

0.0093

0.0140

0.0140

0.0093

0.0140

0.0093

0.0175

Max. platform size

mm

300 x 300

Sensitivity (Cn)

mV/V mV/V

2.2 0.2

Zero signal

0 0.12

Temperature effect on sensitivity (TKC) 2)

in the temperature range

+20 ... +40 °C [+68 ... +104 °F]

- 10 ... +20 °C [+14 ... +68 °F]

% of Cn

/ 10K

0.0175

0.0117

Relative reversibility error (dhy) 2)

% of Cn

% of Cn

% of Cn

% of Cn

0.0166

Non-linearity (dlin) 2)

0.0166

Ratio of minimum dead load output return (DR)

0.0245

Off-center load error 3)

0.0233

Input resistance (RLC)

300...500

Output resistance (R0)

300...500

Reference excitation voltage (Uref)

V

V

5

Nom. range of excitation voltage (BU)

1 ... 12

Isolation resistance (Ris) at 100 VDC

GΩ

> 2

Nominal (rated) range of ambient temperature (BT)

°C [°F]

°C [°F]

°C [°F]

- 10 ... +40 [+14 ... +104]

Operating temperature range (Btu)

- 10 ... +50 [+14 ... +122]

Storage temperature range (Btl)

- 25 ... +70 [- 13 ... +158]

Limit load (EL) *)

*) at max. eccentricity

%

of Emax mm

%

150

100

Lateral load limit (Elq), static

of E% of E

300

Breaking load (Ed)

300

Nominal (rated) displacement at Emax (snom), approx.

mm

< 0.5

Weight (G), approx.

kg

0.25

Degree of protection acc. to EN 60 529 (IEC 529)

IP67

Material: Measuring body

Application protection Cable sheath

Aluminum

Silicone rubber PVC

Single Point Load Cell PW6C - datasheet PDF, 0.16 Kb