KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Single Point Load Cell SP4M

Special features

  • Accuracy class C3MR and C6MR with OIML-R60 test report
  • Off center load compensated (OIML R 76)
  • Degree of protection IP67 (according to EN 60 529)
  • Shielded connection cable
  • Suitable for multi range applications
  • Optional:

  • Explosion proof versions
  • Different cable lenghts
  • Aligned output, suitable for connection in parallel

Type

SP4M...

Accuracy class1)

C3MR

Max. number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2)

kg

1

3

5

7

10

15

20

30

50

75

100

150

200

Minimum LC verification interval (vmin)

g

0.1

0.2

0.5

0.5

1

1

2

2

5

5

10

10

20

Temperature effect on zero balance (TK0)

% v. Cn

/10 K

±0.0140

±0.0093

±0.0140

±0.0100

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

Maximum platform size

mm

300X300

450X450

600X600

Sensitivity (Cn)

Maximum capacity 1 kg

Maximum capacities 3 kg ...200 kg

mV/V

1.8 +15 %; −10 % (Option 6: A1 = 1.8 mV/V±0.1 %)

2.0±10 % (Option 6: A = 2mV/V±0.1 %)

Zero balance

0±0.1

Temperature effect on sensitivity (TKC)3)

Temperature, range +20...+40 °C [+68...+104 °F]

−10...+20 °C [+14...+68 °F]

% of Cn

/10 K

±0.0175

±0.0117

Non-linearity (dlin)3) Hysteresis error (dhy)3)

Minimum dead load output return (MDLOR)

Off center load error4)

% of Cn

±0.0166

±0.0166

±0.0166

±0.0233

Input resistance (RLC) Output resistance (R0)

W

300...500

300...500 (Option 6: A = 410 W±0.2 W)

Reference excitation voltage (Uref)

V

5

Nom. range of excitation voltage (BU) Max. excitation voltage

1 ... 12

15

Isolation resistance (Ris) at 100 VDC

GW

>2

Nom. (rated) range of ambient temperature (BT) Operating temperature range (Btu)

Storage temperature range (Btl)

°C [°F]

−10 ... +40 [+14...+104]

−10 ... +50 [+14...+122]

−25 ... +70 [−13...+158]

Limit load (EL)

Lateral load limit (Elq), static Breaking load (Ed)

% of Emax

150

300

300

Nominal (rated) displacement at Emax (snom), approx.

mm

< 0.5

< 0.3

< 0.25

Weight (G), approx.

kg

0.45

Degree of protection acc. to EN 60 529 (IEC 529)

IP67

Material: Measuring body

Application protection Cable sheath

Aluminum Silicone rubber PVC

Single Point Load Cell SP4M - datasheet PDF, 0.21 Kb