KontrollVahend ja Tehnika (KVT) OÜ
Exclusive representative
Hottinger Baldwin Messtechnik GmbH, Germany
+372 6006190
+372 6006680


Products

Digital Load Cell FIT®7A

Special features

  • Accuracy class up to C4 and maximum scale interval factor Y up to 40,000 with OIML R60 test report (“Test Certificate” extension in preparation)
  • Off−center load compensated (OIML R76)
  • Dosing mode
  • 4 limit value switches
  • Trigger mode (external or level)
  • Automatic parameterization for dynamic applications
  • Stainless steel
  • Degree of protection IP66
  • Integral overload protection
  • PC software for parameter setup and dynamic analysis
  • Various options and accessories are available

Type

FIT7A

Accuracy class 1)

C3

3000

Number of load cell verification intervals

nLC

Fraction

Plc

0.8

Maximum capacity

Emax

kg

3

5

10

20

30

50

75

Minimum load cell verification interval (standard and option 6 = VA)

vmin

g

0.5

1

2

5

10

Maximum scale interval factor Y (standard and option 6 = VA)

Y

6000

10,000

6000

10,000

7500

Temperature coefficient of the zero signal per 10 K 3) (standard and option 6 = VA)

TC0

% of

Cn

±0.0266

±0.0160

±0.0266

±0.0160

±0.0213

Maximum platform size (L x W)

mm

400 x 400

600 x 500

Nominal (rated) sensitivity

Cn

digit

1,000,000

Zero signal

0 ±100,000

Temperature coefficient of the sensitivity per 10 K 4) in the temperature range

+20 … +40°C

−10 … +20°C

TCS

% of

Cn

±0.0200

±0.0133

Non-linearity 4)

dlin

±0.0166

Relative reversibility error 4)

dhy

±0.0166

Minimum dead load output return

MDLOR

±0.0166

Off-load error 2)

±0.0166

Nominal (rated) ambient temperature range

BT

°C

−10 … +40

Nominal (rated) ambient temperature range in option 6 = VC

BT

+5 … +40

Operating temperature range

Btu

−10 … +50

Storage temperature range

Btl

−10 … +70

Limit load at 20 mm eccentricity

EL

% of

Emax

1000

Service load at centric load input

150

Relative vibrational stress at max. 50 mm eccentricity

Fsrel

70

Nominal (rated) displacement 5)

snom

mm

<0.1

Weight, approx.

G

kg

3

Degree of protection per DIN EN 60 529 (IEC 529)

IP66 6)

Voltage supply

Operating voltage (DC) Power consumption Start-up current

UB

V W A

+10 … +30

:::2

<0.2

Material

Housing Diaphragm Bonded seals Base plate

Stainless steel 1.4545 7) Silicone rubber R830 Stainless steel 316L 8) Stainless steel 1.4301 7)

Digital Load Cell FIT®7A - datasheet PDF, 0.18 Kb